Quality Assurance and Average Glandular dose Measurement in Mammography Units

نویسندگان

  • C. Senthamil Selvan
  • C. S. Sureka
چکیده

To ensure the safe operation of mammography units, acceptance tests and quality assurance (QA) protocols have been developed by the American Association of Physicists in Medicine (AAPM), Engineers Registration Board, and International Atomic Energy Agency. Eight mammography units manufactured by five different manufacturers located in hospitals in our region were investigated following the AAPM and Atomic Energy Regulatory Board (AERB) protocols using a solid-state dosimeter-based PTW-NOMEX Multimeter and a metal-oxide-semiconductor field-effect transistor. This study evaluated different operating parameters through mechanical test, accelerating voltage (kVp) accuracy test, machine output measurement, half-value layer measurement, calibration of compression device, image quality assessment, measurement of leakage radiation, radiation survey, and average glandular dose (AGD) measurements using stereotactic needle biopsy phantom. The results show that out of eight mammography units, only a single mammography unit (U-1) passed all QA tests and 2 units passed 7 tests, 2 units passed 6 tests, and 3 units passed 5 tests out of 8 QA tests. In unit 5, the AGD value was 4 and 1.93 mGy before and after service, respectively. QA programs as recommended by AAPM and AERB should be carried out periodically to ensure safety in breast cancer screening. This work points to the importance of the regulation and effective compliance and also help in both improving the QA and reduce the glandular dose received by the patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of mean glandular dose in mammography.

The routine assessment of patient dose in the National Health Service Breast Screening Programme is performed as part of the quality assurance protocol recommended by the Institute of Physical Sciences in Medicine. The mean glandular dose to a standard breast is deduced from measurement of the air kerma at the entrance surface of a 4 cm Perspex phantom by applying a series of conversion factors...

متن کامل

Calculation of Absorbed Glandular Dose using a FORTRAN Program Based on Monte Carlo X-ray Spectra in Mammography

Introduction: Average glandular dose calculation in mammography with Mo-Rh target-filter and dose calculation for different situations is accurate and fast. Material and Methods: In this research, first of all, x-ray spectra of a Mo target bombarded by a 28 keV electron beam with and without a Rh filter were calculated using the MCNP code. Then, we used the Sobol-Wu parameters to write a FORTRA...

متن کامل

Determination of Average Glandular Dose in Mammography for Rh-Rh Mammogram Using Sobol-Wu Parameters in FORTRAN Code

Introduction: To write a computational program to calculate the average glandular dose in Mammography with Rh-Rh target-filter and also use it as an accurate and fast method of dose calculation founder different situations. Materials and Methods: In this research, the Sobol-Wu parameters are used to write a FORTRAN code for glandular dose calculation in Rh-Rh target-filter mammograms. The code ...

متن کامل

نتایج یک کُد فرترن برای محاسبه دوز غده‌ای در ماموگرافی با استفاده از پارامترهای Sobol-Wu

Background: Accurate computation of the radiation dose to the breast is essential to mammography. Various the thicknesses of breast, the composition of the breast tissue and other variables affect the optimal breast dose. Furthermore, the glandular fraction, which refers to the composition of the breasts, as partitioned between radiation-sensitive glandular tissue and the adipose tissue, also h...

متن کامل

Estimation of Mean Estimation of Mean Glandular Dose in Mammography Examination in some of Radiology Centers in Tehran city

Introduction: the objectives of this research were determination of Mean Glandular Dose in film- screen and digital mammography examinations, estimation of accumulated effective dose in some of mammography centers in Tehran city and estimating cancer risk due to these examinations. Materials and Methods: the clinical data were collected from the 1318 <...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 42  شماره 

صفحات  -

تاریخ انتشار 2017