Activity measurements of the radionuclide 99 Tcm for the PTB , Germany in the ongoing comparison BIPM . RI ( II ) - K 1 . Tc - 99

نویسندگان

  • G. Ratel
  • C. Michotte
  • K. Kossert
  • H. Janßen
چکیده

In 2005, the Physikalisch-Technische Bundesanstalt (PTB), Germany, submitted an ampoule with about 79 MBq activity of Tc to the International Reference System (SIR) for activity comparison at the Bureau International des Poids et Mesures (BIPM), to update their value in the key comparison database for the BIPM.RI(II)-K1.Tc-99m comparison. A graphical presentation is also given of the results for all six NMI participants.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Update of the BIPM comparison BIPM . RI ( II ) - K 1 . Ho - 166 m activity measurements of the radionuclide 166 m Ho for

The PTB submitted directly to the SIR one ampoule of 166m Ho prepared from a dilution of the solution distributed to four laboratories participating in the EURAMET.RI(II)-K2.Ho-166m comparison in 2013. No attempt to evaluate a new KCRV has been made and the usual procedure was applied to link the results of the comparison to the usual SIR entries through the PTB. One NMI used this K2 comparison...

متن کامل

BIPM comparison BIPM . RI ( II ) - K 1 . Fe - 59 of the activity measurements of the radionuclide 59 Fe

Since 1976, ten national metrology institutes (NMI) and another laboratory have submitted twenty-one samples of known activity of Fe to the International Reference System (SIR) for activity comparison at the Bureau International des Poids et Mesures. The activities ranged from about 200 kBq to 20 MBq. The degrees of equivalence between each equivalent activity measured in the SIR and the key co...

متن کامل

بررسی گره های گرم تیروئید با اسکن تکنیسیوم 99 و ید-131

Thyroid scintigraphy has been helpful in detecting and evaluation of thyroid nodules. Sodium pertechnetate Tc-99m is the most commonly used radionuclide for thyroid imaging because of its general availability, favorable dosimetric characteristics and low cost. But, there are reports of occasional disparity in isotope uptake in lesions compared with radioiodide. In order to determine percentage ...

متن کامل

Comparison of the Josephson Voltage Standards of the PTB and the BIPM

A comparison of the Josephson array voltage standards of the Bureau International des Poids et Mesures (BIPM) and the Physikalisch-Technische Bundesanstalt (PTB), Braunschweig, Germany, was carried out in October 2014 at the level of 10 V. For this exercise, options A and B of the BIPM.EM-K10.b comparison protocol were applied. Option B required the BIPM to provide a reference voltage for measu...

متن کامل

Determination of 99Mo contamination in 99mTc elute obtained from 99Mo / 99mTc- generator

Background: 99mTc is a widely used radioisotope in nuclear medicine centers which is obtained by elution from Mo-99/Tc-99m generators. Usually the generators are either supplied by the Iran Atomic Energy Agency or by private companies from foreign countries. In this study we have measured 99Mo contamination in 99mTc elute from different generators in a period of one year. Materials and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006