Microchip capillary electrophoresis for point-of-care analysis of lithium.
نویسندگان
چکیده
BACKGROUND Microchip capillary electrophoresis (CE) is a promising method for chemical analysis of complex samples such as whole blood. We evaluated the method for point-of-care testing of lithium. METHODS Chemical separation was performed on standard glass microchip CE devices with a conductivity detector as described in previous work. Here we demonstrate a new sample-to-chip interface. Initially, we took a glass capillary as a sample collector for whole blood from a finger stick. In addition, we designed a novel disposable sample collector and tested it against the clinical standard at the hospital (Medisch Spectrum Twente). Both types of collectors require < 10 microL of test fluid. The collectors contain an integrated filter membrane, which prevents the transfer of blood cells into the microchip. The combination of such a sample collector with microchip CE allows point-of-care measurements without the need for off-chip sample treatment. This new on-chip protocol was verified against routine lithium testing of 5 patients in the hospital. RESULTS Sodium, lithium, magnesium, and calcium were separated in < 20 s. The detection limit for lithium was 0.15 mmol/L. CONCLUSIONS The new microchip CE system provides a convenient and rapid method for point-of-care testing of electrolytes in serum and whole blood.
منابع مشابه
Quantitative Microchip Capillary Electrophoresis for Inorganic Ion Analysis at the Point of Care
No part of this work may be reproduced by print, photocopy or any other means without the permission in writing from the author. 1.2 Microchip capillary electrophoresis of inorganic ions for point-of-care analysis ..6
متن کاملImproved Precision Using Internal Standards in Disposable Point-of-care Capillary Electrophoresis Devices
This paper presents a systematic investigation of the viability of using internal standards to correct for chip-to-chip imprecision in disposable microchip capillary electrophoresis (μCE) devices. The effects of two internal standards (CsCl and LiCl) on the reproducibility of Na quantification were explored using inhouse fabricated microchips. Five concentrations of NaCl were analyzed consecuti...
متن کاملThe Development of a Point of Care Creatinine Measurement Using Disposable Ready to Use Microchip Capillary Electrophoresis
We report on the determination of creatinine in human serum using a point-of-care device suitable for the use by untrained operators, the Medimate Multireader®. This device is based on electrophoretic separation and conductivity detection and its prefilled microfluidic chip has a single opening for sample introduction. The device was originally developed for the determination of lithium in bloo...
متن کاملContactless conductivity detector for microchip capillary electrophoresis.
A microfabricated electrophoresis chip with an integrated contactless conductivity detection system is described. The new contactless conductivity microchip detector is based on placing two planar sensing aluminum film electrodes on the outer side of a poly(methyl methacrylate) (PMMA) microchip (without contacting the solution) and measuring the impedance of the solution in the separation chann...
متن کاملIntegrating Internal Standards into Disposable Capillary Electrophoresis Devices To Improve Quantification
To improve point-of-care quantification using microchip capillary electrophoresis (MCE), the chip-to-chip variabilities inherent in disposable, single-use devices must be addressed. This work proposes to integrate an internal standard (ISTD) into the microchip by adding it to the background electrolyte (BGE) instead of the sample-thus eliminating the need for additional sample manipulation, mic...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 53 1 شماره
صفحات -