Image deconvolution has been widely used in optical microscopy to improve image resolution and enhance contrast, mainly for 3D optically sectioned images. 2D images can be deconvolved in a similar way, and in many circumstances, such processing is either necessary or sufficient. Confocal microscope image slices can be processed as 2D images, especially if the pinhole is opened slightly to increase signal intensity while sacrificing some resolution [1]. Widefield microscope images of thin specimens with a thickness less than the depth of field of the objective lens, and TIRF (Total Internal Reflection Fluorescence) microscope images, in which only structures on the slide surface are illuminated, are also very suitable for 2D deconvolution. The point spread function (PSF) is assumed unknown, so an iterative blind deconvolution approach is used, based on the maximum likelihood expectation maximization (MLEM) method [2]. A vector extrapolation algorithm is employed for acceleration [3], and together with an efficient algorithm implementation, has reduced processing times for a 256x256 pixel image to 2 seconds (for 20 iterations) with a Pentium IV 2GHz CPU. In time-series processing, once the PSF has been estimated from a single frame it can be reused with subsequent frames, further reducing processing times. In addition, a real-time linear filtering method has been developed that allows 512 by 512 pixel images to be processed at up to 30 frames per second. The resulting increase in image contrast enhances low-light level imaging by revealing fine features while the user is exploring the specimen, and potentially enabling the illumination intensity to be reduced. Hybrid methods have been developed that combine the robustness of MLEM, with the speed of Gold’s algorithm, resulting in a 3-5 times faster convergence than the standard MLEM. Wavelet based denoising methods have been adapted to handle the Poisson noise typical in lowlight microscope images and integrated in the deconvolution framework. These denoising methods significantly improve the overall deconvolution quality, and stabilize the result from deteriorating when over-iterated. A dynamic stopping criterion is essential in automating the deconvolution. To achieve this, a set of characteristics including the signal-to-noise ratio, the total variation, and relative image change are computed, and a voting procedure is applied to determine whether to terminate the computation. Combined with the stabilized performance introduced by denoising, automatic termination near the optimal result can be achieved. Results from a variety of microscope modalities, including multi-channel and time-lapse imagery will be presented.
منابع مشابه
Quantification in optical sectioning microscopy: a comparison of some deconvolution algorithms in view of 3D image segmentation
Optical microscopy allows us to study living fluorescent biological samples. Optical sectioning is a technique to obtain three-dimensional (3D) information about the observed object by acquiring a stack of two-dimensional (2D) images at different depths through the sample. However, the specific shape of the 3D optical transfer function of the optical microscope leads to images presenting defect...
متن کاملAPEX blind deconvolution of color Hubble space telescope imagery and other astronomical data
Alfred S. Carasso National Institute of Standards and Technology Mathematical and Computational Sciences Division Gaithersburg, Maryland 20899 E-mail: [email protected] Abstract. The APEX method is a noniterative direct blind deconvolution technique that can sharpen certain kinds of high-resolution images in quasi real time. The method is predicated on a restricted class of blurs, in the ...
متن کاملBlind Correction of Optical Aberrations
Camera lenses are a critical component of optical imaging systems, and lens imperfections compromise image quality. While traditionally, sophisticated lens design and quality control aim at limiting optical aberrations, recent works [1,2,3] promote the correction of optical flaws by computational means. These approaches rely on elaborate measurement procedures to characterize an optical system,...
متن کاملBlind Deconvolution in 3d Biological Microscopy
Confocal microscopy o ers several advantages over conventional optical microscopy with its small depth-ofeld, its reduction of out-of-focus blur, and its full three-dimensional (3D) image scanning ability. For biomedical applications, it can also acquire images of living cells, usually labeled with one or more uorescent probes. The confocal laser scanning microscope (CLSM) is an optical uoresce...
متن کاملLearning Blind Deconvolution
In this work, we propose a novel prior term for the regularization of blind deblurring methods. The proposed method introduces machine learning techniques into the blind deconvolution process. The proposed technique has sound mathematical foundations and is generic to many inverse problems. We demonstrate the usage of this regularizer within Bayesian blind deconvolution framework, and also inte...