Quality Control of Scintillation Cameras (Planar and SPECT)

نویسنده

  • Michael K. O’Connor
چکیده

The purpose of quality control (QC) is to detect changes in the performance of a gamma camera system that may adversely affect the interpretation of clinical studies. Clearly, there are a large number of factors that contribute to the final image quality, including uniformity, resolution (both intrinsic and energy), collimation and the hard copy device. In addition, for certain types of studies, other factors such as count rate capability come into play. With the addition of tomographic imaging, comes an additional suite of parameters that can influence the clinical images these include system center of rotation, gantry and collimator hole alignment, rotational stability of the detector head and the integrity of the reconstruction algorithms. On a day-to-day basis, there is a limited amount of time that can be reasonably devoted to system QC. Hence the main goal of a QC program should be to monitor those parameters that are a) most sensitive to changes in system performance and b) most likely to impact clinical studies. This review will focus on some of the more critical areas in the quality control of gamma camera systems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Acceptance testing and quality control of gamma cameras, including SPECT.

The measurement of several performance parameters of a scintillation camera at the time of installation and thereafter at regular intervals is necessary to ensure that the camera is operating within specifications and to detect changes over time that can initiate a request for service. There are varied opinions on what constitutes a satisfactory acceptance test and quality control program. Few ...

متن کامل

Scintillation camera quality control, Part I: Establishing the quality control program.

This is the first article in a four-part series on scintillation camera quality control. This series of articles will include both theory and practical knowledge on setting up a quality control program, acceptance testing and quality control for planar, SPECT and special imaging procedures. On completion of this article the reader should be able to: (a) discuss the purpose of a quality control ...

متن کامل

Monte Carlo Study of the Effect of Backscatter Materail Thickness on 99mTc Source Response in Single Photon Emission Computed Tomography

Introduction SPECT projections are contaminated by scatter radiation, resulting in reduced image contrast and quantitative errors. Backscatter constitutes a major part of the scatter contamination in lower energy windows. The current study is an evaluation of the effect of backscatter material on FWHM and image quality investigated by Monte Carlo simulation. Materials and Methods SIMIND program...

متن کامل

Evaluation of iterative reconstruction method and attenuation correction on brain dopamine transporter SPECT using anthropomorphic striatal phantom

Objective(s): The aim of this study was to determine the optimal reconstruction parameters for iterative reconstruction in different devices and collimators for dopamine transporter (DaT) single-photon emission computed tomography (SPECT). The results were compared between filtered back projection (FBP) and different attenuation correction (AC) methods.Methods: An anthropomorphic striatal phant...

متن کامل

Performance and Acceptance Testing of Scintillation Cameras for SPECT

This is the third in a series of four continuing education articles related to the characteristics of the scintillation camera. Upon completion of this article, the reader should be able to: 1) understand the principles and the necessity of performance testing; 2) have the basic information to establish and conduct a routine testing program; and 3) effectively ensure the installation and perfor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999