Quantitative cervical spinal cord 3T proton MR spectroscopy in multiple sclerosis.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Brain proton MR spectroscopy ((1)H-MR spectroscopy) is a useful technique for evaluating neuronal/axonal damage and demyelization in multiple sclerosis (MS). Because MS disability is frequently related to spinal cord lesions, potential markers for MS stage differentiation and severity would require in vivo quantification of spinal integrity. However, few spectroscopy studies have investigated cervical disease due to technical difficulties. The present study used 3T (1)H-MR spectroscopy to measure the main metabolites in cervical spinal cord plaques of a group in patients with relapsing-remitting MS (RRMS) and compared them with metabolite measurements in healthy volunteers. MATERIALS AND METHODS A (1)H-MR point-resolved spectroscopy sequence volume of interest was prescribed along the main axis of the cord between C2 and C3 levels on a plaque in a group of 15 patients with RRMS for a total acquisition time of approximately 14 minutes. MR spectroscopy data were analyzed by the user-independent fitting routine LCModel, and relative metabolite concentrations were expressed by the absolute concentration ratios. A Student t test was used to evaluate the difference compared with the healthy metabolite content previously published. RESULTS We found a significant decrease of total N-acetylaspartate/choline and an increase in choline/creatine and myo-inositol/creatine content on MS plaques in comparison with healthy cervical spine tissue. CONCLUSIONS In vivo (1)H-MR spectroscopy, if confirmed by other similar studies, should be as reliable for clinical studies as it is in brain imaging. Moreover, (1)H-MR spectroscopy allows examination of spinal cord integrity at a biochemical level and may be sensitive to subtle changes occurring during the course of MS disease.
منابع مشابه
In vivo 1H-MR Spectroscopy of the mouse cervical spinal cord
Introduction In vivo proton magnetic resonance spectroscopy (MRS) is a unique method for non invasive assessment of healthy and pathologic tissue metabolism. Spinal cord (SC) MRS has been reported in human studies [1-4], as well as in rats [5-6], however, no reports have been performed on mice although it should help, in addition to MRI, in the description of the numerous mouse models of SC dis...
متن کاملProton Density MRI Increases Detection of Cervical Spinal Cord Multiple Sclerosis Lesions Compared with T2-Weighted Fast Spin-Echo.
BACKGROUND AND PURPOSE There is a paucity of literature that supports the Consortium of Multiple Sclerosis Centers guideline that proton density MR imaging is a core spinal cord sequence. We hypothesized that proton density fast spin-echo imaging is superior to T2 fast spin-echo MR imaging for the detection of cervical cord MS lesions. This study compared the detection rate and conspicuity of c...
متن کاملDouble inversion recovery sequence of the cervical spinal cord in multiple sclerosis and related inflammatory diseases.
BACKGROUND AND PURPOSE MR imaging plays an important role in diagnosing MS and other related inflammatory diseases; however, imaging of the spinal cord is still challenging. We hypothesized that a 3D double inversion recovery sequence for cervical spinal cord imaging would be more sensitive in detecting inflammatory lesions than a conventional 2D T2-weighted TSE sequence at 3T. MATERIALS AND ...
متن کاملFast and Accurate Semi-Automated Segmentation Method of Spinal Cord MR Images at 3T Applied to the Construction of a Cervical Spinal Cord Template
OBJECTIVE To design a fast and accurate semi-automated segmentation method for spinal cord 3T MR images and to construct a template of the cervical spinal cord. MATERIALS AND METHODS A semi-automated double threshold-based method (DTbM) was proposed enabling both cross-sectional and volumetric measures from 3D T2-weighted turbo spin echo MR scans of the spinal cord at 3T. Eighty-two healthy s...
متن کاملSpinal cord lesions in patients with multiple sclerosis: comparison of MR pulse sequences.
PURPOSE To compare T2-weighted conventional spin-echo (CSE), fast spin-echo (FSE), shorttau inversion recovery (STIR) FSE, and fluid-attenuated inversion recovery (FLAIR) FSE sequences in the assessment of cervical multiple sclerosis plaques. METHODS Twenty patients with clinically confirmed multiple sclerosis and signs of cervical cord involvement were examined on a 1.5-T MR system. Sagittal...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 31 1 شماره
صفحات -
تاریخ انتشار 2010