GAVeCeLT* consensus statement on the correct use of totally implantable venous access devices for diagnostic radiology procedures.

نویسندگان

  • Giorgio Bonciarelli
  • Stefano Batacchi
  • Roberto Biffi
  • Massimo Buononato
  • Bruno Damascelli
  • Flavio Ghibaudo
  • Franco Orsi
  • Mauro Pittiruti
  • Giancarlo Scoppettuolo
  • Alessia Verzè
  • Guido Borasi
  • Marcello De Cicco
  • Roberto Dosio
  • Paolo Gazzo
  • Renzo Maso
  • Alessandro Roman
  • Vladimira Ticha
  • Giacomo Venier
  • Paul Blackburn
  • Godelieve A Goossens
  • Jamie Bowen Santolucito
  • Marguerite Stas
  • Ton Van Boxtel
  • Thomas M Vesely
  • Enrico de Lutio
چکیده

The use of totally implantable venous access devices in radiology may be associated with complications such as occlusion of the system (because of the high density of some contrast), infection (if the port is not handled in aseptic conditions, using proper barrier protections), and mechanical complications due to the high-pressure administration of contrast by automatic injectors (so-called power injector), including extravasation of contrast media into the soft tissues, subintimal venous or myocardial injection, or serious damage to the device itself (breakage of the external connections, dislocation of the non-coring needle, or breakage of the catheter). The last problem - i.e., the damage of the device from a power injection - is not an unjustified fear, but a reality. A warning by the US Food and Drug Administration of July 2004 reports around 250 complications of this kind, referring to both port and central venous catheters and peripherally inserted central catheter systems, which occurred over a period of several years; in all cases, the damage occurred during the injection of contrast material by means of power injectors for computed tomography or magnetic resonance imaging procedures. Though the risk associated with the use of ports in radiodiagnostics is thus clear, it has been suggested that administration of the contrast material via the port may have some advantage in terms of image quality, increased comfort for the patient, and maybe more accurate reproducibility of the patient's own follow-up exams. This contention needs to be supported by evidence. Also, since many cancer patients who need frequent computed tomography studies already have totally implantable systems, it would seem reasonable to try to define how and when such systems may safely be used. The purpose of this consensus statement is to define recommendations based on the best available evidence, for the safe use of implantable ports in radiodiagnostics.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effectiveness of Permanent Implantable Catheter (Polysite) in Children with Cancer

Abstract Background Totally implantable central venous access devices (ports) have been available for over 10 years, but have not been achieved widespread use in pediatric oncology patients. Ports facilitate the administration of chemotherapy in children with cancer. Materials and Methods In this study, early complications of implantable central venous access devices in children with diff...

متن کامل

Implantable Port Devices, Complications and outcome in Pediatric Cancer, a Retrospective Study

Abstract Background Peripheral blood vessels, due to availability are used for many years in cancer patients, however in patients with potentially harmful drugs to skin (vesicant drugs) or difficult accessibility to vessels, the use of implantable port (totally implantable venous access port-TIVAP)devices with central vascular access are important.  ...

متن کامل

Flushing ports of totally implantable venous access devices, and impact of the Huber point needle bevel orientation: experimental tests and numerical computation

The use of totally implantable venous access devices developed as a medical device allowing mid- and long-term, frequent, repeated, or continuous injection of therapeutic products, by vascular, cavitary, or perineural access. The effective flushing of these devices is a central element to assure long-lasting use. Our experimental work demonstrates that directing the Huber point needle opening i...

متن کامل

Evidence-based criteria for the choice and the clinical use of the most appropriate lock solutions for central venous catheters (excluding dialysis catheters): a GAVeCeLT consensus.

BACKGROUND The most appropriate lock solution for central venous access devices is still to be defined. GAVeCeLT - the Italian group for venous access devices - has developed a consensus on the evidence-based criteria for the choice and the clinical use of the most appropriate lock solution for central venous catheters (excluding dialysis catheters). METHOD After the constitution of a panel o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The journal of vascular access

دوره 12 4  شماره 

صفحات  -

تاریخ انتشار 2011