Effects of heart rate, filling and slice thickness on the accuracy of left ventricular volume measurements in a dynamic cardiac phantom using ECG-gated MDCT.
نویسندگان
چکیده
The objective of the study was to assess the effect of heart rate, filling condition and slice thickness on the accuracy of volumetric analysis based on multidetector-row computed tomography (MDCT) of a cardiac phantom. Retrospective electrocardiogram-gated MDCT of a pulsating phantom was performed under different conditions. End-diastolic volume (EDV) and end-systolic volume (ESV) for different heart rates (60-75 beats per minute), filling volumes and reconstructed slice thicknesses (2 mm and 5 mm) were obtained by three observers. Results were analysed by a linear mixed-effects model. Significant effects on the accuracy were found for heart rate (F-value, 7.3-39.2; p<0.004) and filling condition (F-value, 7.4-55.6; p<0.004), but not for slice thickness. Small relative differences in the assessment of EDV were found (range, -3% to 3%), but there was a trend for overestimation of the ESV (range, -1% to 18%). Underestimation of stroke volume and ejection fraction (range, -1% to -11%) became smaller under conditions of improved temporal resolution and larger EDV. Good interobserver agreement was found (SD <1.8 ml and <0.5%). In conclusion, MDCT allows sufficient and reliable measurements of ventricular volumes and calculation of left ventricle function for clinical applications. Heart rate and filling conditions significantly affect the accuracy of volumetrics, as demonstrated in this cardiac phantom. Thicker slices provide similar accuracy to thin slices.
منابع مشابه
Diastolic left ventricular functional indices: Comparison between gated myocardial perfusion SPECT and echocardiography
Introduction: Many patients have only diastolic dysfunction without any abnormality in systolic function. We compared cardiac diastolic parameters obtained by gated myocardial perfusion SPECT (Gated SPECT) with those evaluated by echocardiography. Methods: Forty-nine patients (aged 37-85 years, 19 males and 30 women) underwent Gated SPECT and echocardiogr...
متن کاملDetection of Cardiac Hypertrophy by RVM and SVM Algorithms
The meaning of the hypertropy word is the increasing size.Heart hypertropy is symptoms of increase the thickness of the heart muscle that the left ventricular hypertrophy of them is the most common.The causes of hypertrophy heart disease are high blood pressure , aortic valve stenosis and sport activities respectively. Assessment of that by using ECG signal analysis is essential Because the ris...
متن کاملComparison of Fetal Echocardiography for Fetal Cardiac Structure in Women with Gestational Diabetes Mellitus and Normal Pregnancies
BackgroundIncreased metabolic rate of hyperglycemia in gestational diabetes causes macrosomia, which can also affect the fetal heart. The thickness of the walls of the heart and its function in women with gestational diabetes mellitus (GDM) can change over time before treatment. We aimed to evaluate fetal cardiac structure in terms of ventricular wall thickness and its function in women w...
متن کاملAssessment of global left ventricular systolic function with multidetector CT and 2D echocardiography: a comparison between reconstructions of 1-mm and 2-mm slice thickness at multidetector CT.
PURPOSE To compare multidetector computed tomography (MDCT) and two-dimensional transthoracic echocardiography (2DE) for left ventricular ejection fraction (EF); and to make comparison between reconstructions of 1-mm and 2-mm slice thickness at MDCT in left ventricular analysis by using a semiautomated segmentation algorithm. MATERIALS AND METHODS In 43 patients global left ventricular systol...
متن کاملEffect of Slice Thickness on the Accuracy of Linear Measurements Made on Cone Beam Computed Tomography Images (InVitro
Objective: Cone beam computed tomography (CBCT) is applied for the imaging of the maxillofacial and dental structures, particularly for surgical treatments and dental implants. The aim of this study was to assess the effect of slice thickness on the accuracy of CBCT linear measurements. Methods: In this diagnostic accuracy study, forty-two titanium pins with the same dimensions were inserted...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The British journal of radiology
دوره 81 967 شماره
صفحات -
تاریخ انتشار 2008