Methylation-specific loop-mediated isothermal amplification for detecting hypermethylated DNA in simplex and multiplex formats.
نویسندگان
چکیده
BACKGROUND Aberrant DNA methylation of gene promoters and the associated silencing of tumor suppressor genes are recognized as mechanisms contributing to tumor development. Therefore, detection of promoter hypermethylation is becoming important for diagnosis, prognosis, and aiding the design of cancer therapies. We describe a novel isothermal method for the detection of DNA hypermethylation. METHODS Methylation-specific loop-mediated isothermal amplification (MS-LAMP) is a novel adaptation of LAMP. MS-LAMP was used for the highly specific detection of hypermethylated CpGs in the promoters of the CDKN2A [cyclin-dependent kinase inhibitor 2A (melanoma, p16, inhibits CDK4)], GATA5 (GATA binding protein 5), and DAPK1 (death-associated protein kinase 1) genes. The reactions occurred under isothermal conditions with 3 primer sets specific for methylated promoters. Both turbidimetry and fluorescence were used for detection. The MS-LAMP assay was validated with bisulfite-treated plasmid and genomic DNA controls of known methylation status and was applied to detect hypermethylation in 18 clinical tumor samples. A multiplex MS-LAMP for CDKN2A, GATA5, and DAPK1 was also validated with the aid of synthetic positive and negative controls. RESULTS The MS-LAMP assay showed high specificity with plasmid and genomic DNA targets in reactions carried out in <1 h. The assay had a detection limit of approximately 30 copies of methylated target sequence and a selectivity of 0.5% methylated DNA in a mixture with unmethylated DNA. Compared with methylation-specific PCR, the MS-LAMP assay detected lower rates of methylation in lung adenocarcinoma samples. Simultaneous multiplex detection of hypermethylation in the 3 targets (CDKN2A, GATA5, and DAPK1) was readily achieved with the MS-LAMP assay in both the turbidimetric and fluorescence detection formats. CONCLUSIONS MS-LAMP provides a highly specific isothermal method for methylation detection and is well suited for multiplex approaches.
منابع مشابه
Loop-Mediated Isothermal Amplification (LAMP) for the Rapid Diagnosis of Herpes Simplex Virus Type 1 (HSV-1)
Background and Aims: considering difficulties in usual laboratory methods in detection of viral infections, improved DNA-based diagnostic techniques are more reliable. Loop mediated isothermal amplification method (LAMP) is a nucleic acid amplification method that amplifies DNA using six primers which has been developed to diagnose viruses as a rapid and high efficiency test. In this study, the...
متن کاملDetermination of Herpetic Keratitis Frequency Using Loop Mediated Isothermal Amplification (LAMP) Method in Isfahan, Iran
Herpetic keratitis which is resulted from herpes simplex virus type I, is considered the most common cause of corneal blindness that needs being diagnosed and treated in order to prevent irreversible eye effects. The best method to diagnose it is molecular method which has high sensitivity and exclusivity. The current study was done on 25 eye samples collected from patients referred to the Feyz...
متن کاملDetermination of Herpetic Keratitis Frequency Using Loop Mediated Isothermal Amplification (LAMP) Method in Isfahan, Iran
Herpetic keratitis which is resulted from herpes simplex virus type I, is considered the most common cause of corneal blindness that needs being diagnosed and treated in order to prevent irreversible eye effects. The best method to diagnose it is molecular method which has high sensitivity and exclusivity. The current study was done on 25 eye samples collected from patients referred to the Feyz...
متن کاملتشخیص و افتراق سریع فاسیولا هپاتیکا و فاسیولا ژیگانتیکا با استفاده از روش loop-mediated Isothermal Amplification
Background and purpose: Fasciola hepatica and Fasciola gigantica are common liver flukes which affect both human and livestock worldwide. In this study we evaluated the loop-mediated isothermal amplification (LAMP) assay for detection and discrimination of Fasciola species. Materials and methods: Fifty adults of Fasciola worms were isolated from sheep and cattle liver form abattoirs in Mazand...
متن کاملSimultaneous multiple target detection in real-time loop-mediated isothermal amplification.
Loop-mediated isothermal amplification (LAMP) is a rapid and reliable sequence-specific isothermal nucleic acid amplification technique. To date, all reported real-time detection methods for LAMP have been restricted to single targets, limiting the utility of this technique. Here, we adapted standard LAMP primers to contain a quencher-fluorophore duplex region that upon strand separation result...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 56 8 شماره
صفحات -
تاریخ انتشار 2010