Transfer precision of three-dimensional implant planning with CT assisted offline navigation.
نویسندگان
چکیده
AIM Computer-assisted surgery (CAS) is used in implant dentistry for preoperative planning and intraoperative transfer of the correct implant position. Implant placement is performed via sleeve-guided templates in the case of static navigation procedures by taking into consideration prosthetics and the amount of local bone. The aim of the present in vitro study was to analyze the transfer precision of the computer-aided planning system Med3D as well as the possible improvement of transfer accuracy by using a second, template-guided drilling during osteotomy. MATERIALS AND METHODS A total of 48 implants were placed into 8 study models from calf ribs. Preoperative computed tomography (CT) scans were imported via the respective software and used for virtual planning of the implant position on the computer. CT control images were taken after the actual implant site preparation via sleeve-guided drilling templates and subsequent implant placement. The preoperative CT scans were compared to the post-operative CT images in order to analyze transfer precision. Vertical, radial and axis deviations were calculated for each implant. RESULTS The minimal deviations obtained between the planned and the achieved implant position have shown that a transfer accuracy within the range of 0.1 mm is feasible when utilizing the MED-3D system. However, maximal vertical deviations of up to 2 mm have to be considered. The maximal axis deviation may reach 16 degrees. Deviations from the planned implant position seem to be influenced especially by the local bone quality and quantity. Transfer precision may be significantly improved by adopting a second, sleeve-guided implant site preparation. CONCLUSION Static procedures allow for a precise transfer of the virtual, computer-assisted implant planning to the surgical site. However, transfer deviations of up to 2 mm in all directions should be considered in order to prevent impairment of anatomical structures. Local bone quality and quantity seem to influence the deviations from the implant position planned. A significant improvement of the transfer precision can be achieved by applying a second sleeve-guided site preparation.
منابع مشابه
Three-dimensional planning and simulation of hip operations and computer-assisted construction of endoprostheses in bone tumor surgery.
OBJECTIVE This article presents the VIRTOPS (VIRTual Operation Planning in Orthopaedic Surgery) software system for virtual preoperative planning and simulation of hip operations. The system is applied to simulate the endoprosthetic reconstruction of the hip joint with hemipelvic replacement, and supports the individual design of anatomically adaptable, modular prostheses in bone tumor surgery....
متن کاملGenauigkeitsanalyse zur navigationsgestützten Planung und Insertion von dentalen Implantaten in Unterkieferkunststoffmodellen
The surgical insertion of dental implants requires careful preoperative diagnostics. Particularly, in morphologically difficult situations a CT scan is most useful for the true to scale three-dimensional imaging of the alveolar process and the implant planning. Using a navigation system we are enabled to transfer the preoperative planning and simulation accurately into the operating situs. In t...
متن کاملVirtual surgical planning and 3D printing in prosthetic orbital reconstruction with percutaneous implants: a technical case report
Osseointegrated titanium implants to the cranial skeleton for retention of facial prostheses have proven to be a reliable replacement for adhesive systems. However, improper placement of the implants can jeopardize prosthetic outcomes, and long-term success of an implant-retained prosthesis. Three-dimensional (3D) computer imaging, virtual planning, and 3D printing have become accepted componen...
متن کاملPrecision and Reliability Incensement of Inertial Navigation System with Rotation and Redundancy
Precision and reliability are two main performance characteristic in low-cost Inertial Navigation System(INS). Increase of precision in low-cost INS without auxiliary sensors is main challenge. Bias instability leads to position drift error in inertial navigation system. In addition, fault occurrence makes the sensor reliability is decreased. Rotation of Inertial Measurement Unit(RIMU) and use ...
متن کاملPreoperative planning for implant placement with consideration of pelvic tilt in total hip arthroplasty: postoperative efficacy evaluation
BACKGROUND In total hip arthroplasty (THA), tilting of the pelvis alters the cup placement angles. Thus, the cup angles need to be planned with consideration of the effects of pelvic tilt. In the present study, we evaluated the efficacy of preoperative planning for implant placement with consideration of pelvic tilt in THA, and the accuracy of a CT-based computer navigation for implant position...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- International journal of computerized dentistry
دوره 11 3-4 شماره
صفحات -
تاریخ انتشار 2008