Comparison of the Adaptive Optics Vision Analyzer and the KR-1 W for measuring ocular wave aberrations.

نویسندگان

  • Carles Otero
  • Meritxell Vilaseca
  • Montserrat Arjona
  • Joan A Martínez-Roda
  • Jaume Pujol
چکیده

BACKGROUND The aim was to assess the agreement in the measurement of ocular aberrations between a new Adaptive Optics Vision Analyzer (AOVA, Voptica, Murcia, Spain) and a commercial aberrometer (KR-1 W, Topcon, Tokyo, Japan), both based on the Hartmann-Shack technique. METHODS One experienced examiner measured 29 healthy right eyes nine consecutive times with the two instruments. The individual Zernike coefficients and the root mean square (RMS) of each order from the second to the fifth order, the higher-order RMS (RMSHOA ), the total RMS (RMSTOT ) and the values of the spherical equivalent (M) and Jackson cross-cylinder (J0 and J45 ) were compared. All aberrations were computed for a 4.0 mm pupil diameter. RESULTS Bland and Altman analysis showed good agreement between instruments and most of the parameters showed no statistically significant differences. Although the largest mean differences were obtained for the defocus coefficient C(2,0) and the spherical equivalent (M) with a mean difference (and standard deviation) of 0.190 ± 0.099 µm and -0.150 ± 0.188 D, respectively, they were clinically acceptable and significant correlations were found between the AOVA and KR-1 W for the major refractive components such as spherical equivalent (r = 0.995, p < 0.001), J0 (r = 0.964, p < 0.001), J45 (r = 0.901, p < 0.001) and C(4,0) (r = 0.575, p = 0.001). CONCLUSION The results suggest good agreement between instruments. Accommodation and misalignment of the measurements may play a role in some of the statistically significant differences that were obtained, specifically for defocus C(2,0), vertical coma C(3,-1) and spherical aberration C(4,0) coefficients; however, these differences were clinically irrelevant.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of ocular aberrations on contrast detection in noise.

We use adaptive optics (AO) techniques to manipulate the ocular aberrations and elucidate the effects of these ocular aberrations on contrast detection in a noisy background. The detectability of sine wave gratings at frequencies of 4, 8, and 16 circles per degree (cpd) was measured in a standard two-interval force-choice staircase procedure against backgrounds of various levels of white noise....

متن کامل

Adaptive optics with a programmable phase modulator: applications in the human eye.

Adaptive optics for the human eye has two main applications: to obtain high-resolution images of the retina and to produce aberration-free retinal images to improve vision. Additionally, it can be used to modify the aberrations of the eye to perform experiments to study the visual function. We have developed an adaptive optics prototype by using a liquid crystal spatial light modulator (Hamamat...

متن کامل

Use of adaptive optics to determine the optimal ocular spherical aberration.

PURPOSE To explore the impact of spherical aberration (SA) on contrast sensitivity using an adaptive optics vision simulator to determine the optimal amount of SA to include in customized corrections of wavefront aberrations. SETTING Laboratorio de Optica, Universidad de Murcia, Murcia, Spain, and AMO Groningen BV, Groningen, The Netherlands. METHODS An adaptive optics vision simulator cons...

متن کامل

Closed-loop adaptive optics in the human eye.

We have developed a prototype apparatus for real-time closed-loop measurement and correction of aberrations in the human eye. The apparatus uses infrared light to measure the wave-front aberration at 25 Hz with a Hartmann-Shack sensor. Defocus is removed by a motorized optometer, and higher-order aberrations are corrected by a membrane deformable mirror. The device was first tested with an arti...

متن کامل

Calibration of a deformable mirror and Strehl ratio measurements by use of phase diversity.

Calibration experiments with a bimorph mirror are presented. Phase-diversity wave-front sensing is used for measuring the control matrix, nulling wave-front errors in the optical setup, including the mirror, and measuring Strehl ratios and residual higher-order aberrations. The Strehl ratio of the calibrated system is measured to be 0.975, corresponding to 1/40 wave rms in the residual wave fro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical & experimental optometry

دوره 100 1  شماره 

صفحات  -

تاریخ انتشار 2017