Effectiveness of pulse oximetry versus fetal electrocardiography for the intrapartum evaluation of nonreassuring fetal heart rate.

نویسندگان

  • Mercedes Valverde
  • Alberto M Puertas
  • María F Lopez-Gallego
  • María P Carrillo
  • María T Aguilar
  • Francisco Montoya
چکیده

OBJECTIVES To compare the effectiveness of pulse oximetry and fetal electrocardiography in the management of labor with nonreassuring fetal heart rate (NRFHR). STUDY DESIGN This randomized experimental study consisted of two arms. In group 1 we used pulse oximetry and in group 2 we used STAN® technology. The participants in each group were 90 pregnant women with a full-term singleton fetus in cephalic presentation and cardiotocographic tracings compatible with NRFHR. We compared the following variables: rate of cesarean delivery, indications for operative delivery due to NRFHR, and repercussions on the newborn's acid-base status. RESULTS The two groups differed significantly in the mode of delivery, with a cesarean delivery rate of 47.6% in group 1 vs. 30% in group 2 (p=0.032). The groups did not differ in the indications for ending labor due to NRFHR (62% vs. 61%, NS). In terms of neonatal outcomes, the 1-min Apgar score was 6 or lower in 17.8% of the group 1 neonates vs. 4.44% of the group 2 neonates (p<0.001). The groups also differed significantly in umbilical cord vein pH (7.23 vs. 7.27) and pCO₂ (57.27 vs. 46.86) at birth. CONCLUSIONS Fetal electrocardiography with the STAN® 21 system was more effective in detecting good fetal status and thus in identifying cases in which labor could proceed safely. Intrapartum surveillance with the STAN® 21 system reduced the rate of emergency cesarean delivery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

General Obstetrics and Gynecology: Obstetrics

Objective: We tested if fetal pulse oximetry in addition to electronic fetal monitoring (CTG) and scalp blood sampling improves the accuracy of fetal assessment and allows safe reduction of operative deliveries ( 50%) and scalp blood sampling ( 50%) performed because of nonreassuring fetal status. Study design: A randomized controlled trial was conducted in 146 patients with term pregnancies in...

متن کامل

Intrapartum fetal surveillance.

Intrapartum hypoxia was thought to contribute to the incidence of cerebral palsy, seizures and mental retardation. Electronic fetal monitoring was expected to prevent or reduce this incidence. Electronic fetal monitoring has a high false positive rate and fetal blood sampling, which is an invasive procedure, only allows an intermittent assessment. Efforts are being made to improve fetal heart r...

متن کامل

Fetal pulse oximetry and cesarean delivery.

BACKGROUND Knowledge of fetal oxygen saturation, as an adjunct to electronic fetal monitoring, may be associated with a significant change in the rate of cesarean deliveries or the infant's condition at birth. METHODS We randomly assigned 5341 nulliparous women who were at term and in early labor to either "open" or "masked" fetal pulse oximetry. In the open group, fetal oxygen saturation val...

متن کامل

Fetal pulse oximetry for fetal assessment in labour.

BACKGROUND Fetal pulse oximetry (FPO) may contribute to the evaluation of fetal well-being during labour. OBJECTIVES To compare the effectiveness and safety of FPO with conventional surveillance techniques, using the results of randomised controlled trials. SEARCH STRATEGY We searched the Cochrane Pregnancy and Childbirth Group trials register (31 July 2004) and conducted a systematic liter...

متن کامل

Trans-abdominal monitoring of fetal arterial blood oxygenation using pulse oximetry.

Pulse oximetry (oxygen saturation monitoring) has markedly improved medical care in many fields, including anesthesiology, intensive care, and newborn intensive care. In obstetrics, fetal heart rate monitoring remains the standard for intrapartum assessment of fetal well being. Fetal oxygen saturation monitoring is a new technique currently under development. It is potentially superior to elect...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of obstetrics, gynecology, and reproductive biology

دوره 159 2  شماره 

صفحات  -

تاریخ انتشار 2011