Determination of mercury in coal by isotope dilution cold-vapor generation inductively coupled plasma mass spectrometry.

نویسندگان

  • Stephen E Long
  • W Robert Kelly
چکیده

A method based on isotope dilution cold-vapor inductively coupled plasma mass spectrometry (ID-CV-ICPMS) has been developed for high-accuracy determinations of mercury in bituminous and sub-bituminous coals. A closed-system digestion process employing a Carius tube is used to completely oxidize the coal matrix and chemically equilibrate the mercury in the sample with a 201Hg isotopic spike. The digestates are diluted with high-purity quartz-distilled water, and the mercury is released as a vapor by reduction with tin(II) chloride. Measurements of 201Hg/202Hg isotope ratios are made using a quadrupole ICPMS system in time-resolved analysis mode. The new method has some significant advantages over existing methods. The instrument detection limit is less than 1 pg/mL. The average blank (n = 17) is 30 pg, which is roughly 1 order of magnitude lower than the equivalent microwave digestion procedure. The detection limit in coal is blank limited and is approximately 40 pg/g. Memory effects are very low. The relative reproducibility of the analytical measurements is approximately 0.5% for mercury concentrations in the range 10-150 ng/g. The method has been used to measure mercury concentrations in six coal reference materials, SRM 1632b (77.4 ng/g), SRM 1632c (94.3 ng/g), BCR 40 (433.2 ng/g), BCR 180 (125.0 ng/g), BCR 181 (135.8 ng/g), and SARM 20 (252.6 ng/g), as well as a coal fly ash, SRM 1633b (143.1 ng/g). The method is equally applicable to other types of fossil fuels including both crude and refined oils.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Direct mercury analysis in environmental solids by ICP-MS with on-line sample ashing and mercury pre-concentration using a direct mercury analyzer

A commercially available direct mercury analyzer (DMA) based on sample combustion, pre-concentration by amalgamation with gold, and atomic absorption spectrophotometry (AAS) was coupled to a sector field inductively coupled plasma mass spectrometer (ICP-MS). The combined system (DMA-ICP-MS) was optimized and evaluated for the determination of mercury in environmental samples using both external...

متن کامل

On the use of certified reference materials for assuring the quality of results for the determination of mercury in environmental samples

This work focused on the development and validation of methodologies for the accurate determination of mercury in environmental samples and its further application for the preparation and certification of new reference materials (RMs). Two certified RMs ERM-CC580 (inorganic matrix) and ERM-CE464 (organic matrix) were used for the evaluation of digestion conditions assuring the quantitative reco...

متن کامل

Determination of 137Ba Isotope Abundances in Water Samples by Inductively Coupled Plasma-optical Emission Spectrometry Combined with Least-squares Support Vector Machine Regression

A simple and rapid method for the determination of 137Ba isotope abundances in water samples by inductively coupled plasma-optical emission spectrometry (ICP-OES) coupled with least-squares support vector machine regression (LS-SVM) is reported. By evaluation of emission lines of barium, it was found that the emission line at 493.408 nm provides the best results for the determination...

متن کامل

Determination of mercury in whole blood and urine by inductively coupled plasma mass spectrometry.

The conventional method for the determination of mercury in clinical samples is cold vapor atomic absorption spectrometry. Sample digestion or pretreatment require large sample volume and long sample preparation time. The inductively coupled plasma mass spectrometry (ICP-MS) method developed in this study requires only 100 microL of sample with practically no preparation, except for dilution wi...

متن کامل

Determination of Cu, Zn, Cd and Pb in ®sh samples by slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry

Ultrasonic slurry sampling electrothermal vaporization isotope dilution inductively coupled plasma mass spectrometry (USSETV-ID-ICP-MS) has been applied to the determination of Cu, Zn, Cd and Pb in several ®sh reference samples. NH4NO3 was added to the sample solution to work as a modi®er. Since the sensitivity of the elements studied in ®sh slurry and aqueous solution was quite different, isot...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical chemistry

دوره 74 7  شماره 

صفحات  -

تاریخ انتشار 2002