Symmetry of electromechanical delay, peak torque and rate of force development in knee flexors and extensors in female and male subjects.

نویسندگان

  • Agnieszka Szpala
  • Alicja Rutkowska-Kucharska
  • Mateusz Stawiany
چکیده

PURPOSE The aim of the study was to evaluate electromechanical delay (EMD), peak torque (PT) and rate of force development (RFD) in selected muscles of right and left lower extremities in groups of female and male subjects. METHODS The study evaluated 9 volunteer female subjects (mean ± SD: age: 21.67 ± 0.87 years; height: 168 ± 7 cm; body mass: 59.44 ± 4.8 kg) and 10 male university students (mean ± SD: age 22 ± 1.25 years; height: 179 ± 6 cm; body mass: 74.3 ± 5.1 kg) from the Faculty of Physical Education. Muscle torques and electromyographic activity were measured for knee flexors and extensors in static conditions, separately for the right and the left lower extremities. During the measurements, the subjects generated the maximum torque as fast as possible. Surface electrodes were placed on the right and left lower extremities on the following muscles: rectus femoris, vastus lateralis (m.VL), vastus medialis and biceps femoris. RESULTS Symmetry of EMD, RFD and "flexors-extensors" ratio was found in the muscles of the right and left lower extremities (with an exception of m.VL) in the group of male and female subjects. Statistical analysis demonstrated the presence of asymmetry in PT (297.66 vs. 272.05 N⋅m) and relative force in knee extensors in the group of men (3.90 vs. 3.54 N⋅m⋅kg-1). CONCLUSIONS Symmetry of EMD and asymmetry of PT might suggest that the cause of asymmetry of the muscular force is mainly morphologi- cal characteristics of the muscle rather than the process of controlling its activity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Isokinetic dynamometry of the knee extensors and flexors in

  Background :This paper explores the gender-related bilateral differences of extensor and flexor torques of the knee joint at low and high angular velocities in Iranian healthy males and females.   Methods : 70 healthy subjects (29 males (26.61±4.34 yrs and 41 females with average age of 23.07±3.70 yrs)) were participated in this study. Isokinetic peak torque values for knee extensors and flex...

متن کامل

Effects of 8 weeks of water-based exercise on the lower limb muscles strength in Parkinson\'s

 Introduction: Muscular weakness, particularly weakness of lower limb muscles is a symptom of Parkinson disease, which, together with other symptoms, will result in a variety of movement disorders. This research is designed to assess the effectiveness of a water-based exercise program on the lower limb muscles strength of Parkinson patients' knee joints. Materials and Methods: In a semi-exp...

متن کامل

Maximal Voluntary and Electrically Stimulated Torque – Angle – Angular Velocity Profiles of the Knee Extensors and Flexors

In vivo measurements of maximum voluntary force – velocity show differences to the in vitro tetanic profile, with eccentric forces not increasing much above isometric and tending to decline with increasing lengthening velocity. Using transcutaneous electrical stimulation maximal eccentric torque has been found to be 1.4 times the isometric value and does not drop off at higher eccentric velocit...

متن کامل

Measurement of fatigue in knee flexor and extensor muscles.

In order to examine fatigue of the knee flexor and extensor muscles and to investigate the characteristics of muscular fatigue in different sports, a Cybex machine was used to measure muscle fatigue and recovery during isokinetic knee flexion and extension. Eighteen baseball players, 12 soccer players and 13 marathon runners were studied. Each subject was tested in the sitting position and made...

متن کامل

The torque-velocity relationship in large human muscles: maximum voluntary versus electrically stimulated behaviour.

The in vivo maximum voluntary torque-velocity profile for large muscle groups differs from the in vitro tetanic profile with lower than expected eccentric torques. Using sub-maximal transcutaneous electrical stimulation has given torque-velocity profiles with an eccentric torque plateau ∼1.4 times the isometric value. This is closer to, but still less than, the in vitro tetanic profiles with pl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta of bioengineering and biomechanics

دوره 17 1  شماره 

صفحات  -

تاریخ انتشار 2015