Evaluation of the enzymatic ammonia method for urine on the Du Pont automatic clinical analyzer.

نویسندگان

  • F R Hindriks
  • A Groen
چکیده

The enzymatic method for ammonia with the Du Pont Automatic Clinical Analyzer was tested in our laboratory. The method is very suitable for urine samples although the method was released by Du Pont only for plasma samples. The results correlated well with those obtained by a method based on the Berthelot indophenol reaction and by a method based on the use of an ammonium electrode, which has an ammonium ion selective membrane. The day-to-day coefficient of variation is about 2 and 4% at concentration levels of 100 and 50 mumol/1 respectively. The measured and relative ammonia concentration are linearly related. Recovery of added known amounts of ammonium is complete and no interference from glucose, urea, creatinine and uric acid could be demonstrated. Recommendations are given for handling blood and urine samples before analysis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated enzymatic assay for plasma ammonia.

An enzymatic method for determining plasma ammonia with the Du Pont Automatic Clinical Analyzer (aca) is described. The assay requires a sample volume of 500 muL for a kinetic ammonia measurement. The reaction is initiated with glutamate dehydrogenase and the rate of depletion of NADPH is monitored with two measurements, 17 s apart, at 340 nm. Reaction conditions have been optimized for maximum...

متن کامل

Evaluation of the revised serum calcium procedure used with the Du Pont automatic clinical analyzer.

We evaluated a revised serum calcium method (o-cresolphthalein complexone) used with the Du Pont aca. Our results correlated well with those obtained by atomic absorption spectrometry. Within-run and day-to-day coefficients of variation were 0.5 and 1.5%, respectively. Color produced and calcium concentration are linearly related and the relation is not affected by hemolysis, lipemia, or icterus.

متن کامل

Automated enzymatic method for determining ammonia in plasma, with 14-day reagent stability.

This is an automated, cost-efficient enzymatic method for determining ammonia in plasma. In most assays for ammonia the reagents are stable for only one or two days at 4 degrees C, but the reagents in our method are stable for at least 14 days. Our method was developed for use with a Cobas-Fara analyzer but can be easily adapted to other automated analyzers. It is essential to use closed sample...

متن کامل

Source of error in cerebrospinal fluid protein determination with the Du Pont Automatic Clinical Analyzer.

To the Editor: The most widely used method for measurement of cerebrospinal fluid (CSF) total protein is turbidimetry. We use the Du Pont Automatic Clinical Analyzer (aca; Du Pont Instruments, Wilmington, Del. 19898) for this measurement. In this method, CSF proteins are precipitated by trichloroacetic acid and the resulting turbidity is measured spectrophotometrically (1). Values are falsely l...

متن کامل

Evaluation of a direct potentiometric method for sodium and potassium used in the Du Pont aca.

We evaluated an accessory that enables the Du Pont aca discrete analyzer to measure Na+ and K+ by direct potentiometry (aca/ISE). Na+ and K+ gave linear responses in both the blood and urine modes, with no carryover. No interfering species were identified in the blood mode. Intra-assay and interassay precision for Na+ and K+ were more than adequate and analytical recoveries comparable to those ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of clinical chemistry and clinical biochemistry. Zeitschrift fur klinische Chemie und klinische Biochemie

دوره 16 5  شماره 

صفحات  -

تاریخ انتشار 1978