Application of a novel rf coil design to the magnetic resonance force microscope
نویسندگان
چکیده
We report a rf coil design based on the Alderman–Grant coil called the modified Alderman–Grant coil ~MAGC!, and demonstrate its efficacy in the magnetic resonance force microscope ~MRFM!. The rf field of the MAGC has a magnitude comparable to that of a solenoidal coil of similar size ~for the same input power! but the coil has a much smaller inductance. This is advantageous in electron spin resonance MRFM experiments which would benefit from rf frequencies in excess of 1000 MHz. The open design of the MAGC is also advantageous because it provides superior access to the sample mounted on a mechanical cantilever by the optical fiber and permanent magnet and so allows the sample to be placed at the center of the coil. © 1996 American Institute of Physics. @S0034-6748~96!02509-9#
منابع مشابه
3-D RF Coil Design Considerations for MRI
High-frequency coils are widely used in medical applications, such as Magnetic Resonance Imaging (MRI) systems. A typical medical MRI includes a local radio frequency transmit/receive coil. This coil is designed for maximum energy transfer or wave transfer through magnetic resonance. Mutual inductance is a dynamic parameter that determines the energy quantity to be transferred wirelessly by ele...
متن کاملStatic Coil Design Considerations for the Magnetic Resonance Imaging
One of the main challenges in developing magnetic resonance imaging (MRI) systems is to create a static coil that needs to generate magnetic field density along with the characteristics of optimal homogeneity and magnitude size. To do this, two N42 Block PMs are used and the iron core is designed and optimized in accordance with the dimensions of PM pieces using ANSYS Maxwell software. Then, al...
متن کاملNon-uniformity of Clinical Head, Head and Neck, and Body Coils in Magnetic Resonance Imaging (MRI)
Introduction Signal intensity uniformity in a magnetic resonance (MR) image indicates how well the MR imaging (MRI) system represents an object. One of the major sources of image non-uniformity in high-field MRI scanners is inhomogeneity of radio-frequency coil. The aim of this study was to investigate non-uniformity in head, head and neck, and body coils and compare the obtained results to det...
متن کاملDesigning and Fabrication of a New Radiofrequency Planar microcoil for mini-Nuclear Magnetic Resonance
Introduction Radiofrequency planar microcoils are used to increase the resolution of magnetic resonance images of small samples. In this study, we aimed to design and fabricate a spiral planar microcoil constructed on a double-sided printed circuit board (PCB). It has four rings with an internal diameter of 241 microns tuned and matched at 63.8 MHz. Materials and Methods To achieve the maximum ...
متن کاملA birdcage coil tuned by RF shielding for application at 9.4 T.
The design and performance of an inductively fed low-pass birdcage radiofrequency (RF) coil for applications at 9.4 T are described where tuning is accomplished by mechanically moving a concentric RF shield about the longitudinal axis of an RF coil. Moving the shield about the RF coil effectively changes the mutual inductance of the system, providing a mechanism for adjusting the resonant frequ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 1996