Exploring effective multiplicity in multichannel functional near-infrared spectroscopy using eigenvalues of correlation matrices.
نویسندگان
چکیده
Recent advances in multichannel functional near-infrared spectroscopy (fNIRS) allow wide coverage of cortical areas while entailing the necessity to control family-wise errors (FWEs) due to increased multiplicity. Conventionally, the Bonferroni method has been used to control FWE. While Type I errors (false positives) can be strictly controlled, the application of a large number of channel settings may inflate the chance of Type II errors (false negatives). The Bonferroni-based methods are especially stringent in controlling Type I errors of the most activated channel with the smallest [Formula: see text] value. To maintain a balance between Types I and II errors, effective multiplicity ([Formula: see text]) derived from the eigenvalues of correlation matrices is a method that has been introduced in genetic studies. Thus, we explored its feasibility in multichannel fNIRS studies. Applying the [Formula: see text] method to three kinds of experimental data with different activation profiles, we performed resampling simulations and found that [Formula: see text] was controlled at 10 to 15 in a 44-channel setting. Consequently, the number of significantly activated channels remained almost constant regardless of the number of measured channels. We demonstrated that the [Formula: see text] approach can be an effective alternative to Bonferroni-based methods for multichannel fNIRS studies.
منابع مشابه
Optical Imaging of the Motor Cortex in the Brain in Order to Determine the Direction of the Hand Movements Using Functional Near-Infrared Spectroscopy (fNIRS)
Introduction: In recent years, optical imaging has attracted a lot of attention from scholars as a non- aggressive, efficient method for evaluating the activities of the motor cortex in the brain. Functional near-infrared spectroscopy (fNIRS (is a tool showing the hemodynamic changes in a cortical area of the brain according to optical principles. The present study has been de...
متن کاملNondestructive Firmness Estimation of Tomato Fruit Using Near-Infrared Spectroscopy
Today, nondestructive methods are widely used to determine the quality of agricultural products. Meanwhile, visible and near-infrared (Vis/NIR) spectroscopy is regarded as one of the most widely used methods in the field of quality assessment of agricultural products. In this study, a system was developed to measure the Vis/NIR spectra of tomato fruit samples in the half-transmittance mode of m...
متن کاملAssessment of cortical hemodynamics by multichannel near-infrared spectroscopy in steno-occlusive disease of the middle cerebral artery.
BACKGROUND AND PURPOSE In a pilot study we evaluated near-infrared spectroscopy as to its potential benefit in monitoring patients with steno-occlusive disease of a major cerebral artery for alterations in cortical hemodynamics. METHODS Cortical maps of time-to-peak (TTP) in 10 patients unilaterally affected by severe stenosis or occlusion of the middle cerebral artery were acquired by multic...
متن کاملCorrelation of intraoperative renal near infrared spectroscopy with the development of acute kidney injury in adult patients undergoing cardiac surgery using cardiopulmonary bypass
Introduction: The present study aimed to correlate renal oximetry near-infrared spectroscopy (NIRS) values with conventional non-invasive biomarkers for the early detection of acute kidney injury (AKI) in adult patients undergoing cardiac surgery using cardiopulmonary bypass (CPB). Accordingly, renal NIRS can be employed as a trending device for the prevention of AKI developmen...
متن کاملDetection of an unstable and/or a weak probe contact in a multichannel functional near-infrared spectroscopy measurement.
Multichannel functional near-infrared spectroscopy measurements involve the placement of many probes on a subject's head. A stable close contact between the probe and head surface is essential. We propose a way to detect two types of problematic probe contacts from the measurement data: an unstable contact whose light transmission easily fluctuates with body motion, and a weak contact whose lig...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Neurophotonics
دوره 2 1 شماره
صفحات -
تاریخ انتشار 2015