Total and Capture Cross Sections of Dysprosium Isotopes up to 20 MeV
نویسندگان
چکیده
Neutron data for total and capture cross sections were evaluated on 160Dy, 161Dy, 162Dy, 163Dy, and 164Dy up to 20 MeV. The resolved resonance parameters were adopted from the Mughabghab compilation, but one bound level resonance for each isotope except 162Dy was invoked to reproduce the reference thermal cross sections. The average resonance parameters for s-wave neutrons were obtained from the analysis of the statistical behavior of resolved resonance parameters. Recent measurements of the capture cross sections were taken into account in adjusting the average resonance parameters for pand d-waves. From the first excited energy to 20 MeV, the optical model, Hauser-Feshbach model, and quantum mechanical models were used to produce total, elastic scattering, and capture cross sections. The energy-dependent optical model potential was decided based on the recent experimental data. The calculated cross sections were in good agreement with the experimental data. The present evaluation resulted in improvement over the ENDF/B-VI.7 code.
منابع مشابه
Proceedings of a Specialists' Meeting on Neutron Cross Section Standards for the Energy Region above 20 Mev
The present status of neutron-proton scattering in the energy range from 20-70 MeV is reviewed. The data base covers total cross sections, differential cross sections and polarization observables. The efforts after 1980 did largely cnncentrate on precision measurements of the differential cross sections and accurate vector analyzing powers, using polarized neutron beams. Because of correlations...
متن کاملEvaluation of Neutron Cross Sections on Eu-153 in the Fast Energy Region
The neutron induced nuclear data for Eu-153 were calculated and evaluated from 1 keV to 20 MeV using Ecis-Empire code combination. The energy dependent optical model potential by Macklin and Young was applied up to 20 MeV. An optical model, the full featured Hauser-Feshbach model, the multistep direct and multistep compound model were used in the calculation. The theoretically calculated cross ...
متن کاملRecent Developments in Nuclear Data Measurement capabilities at the Gaerttner LINAC Center at RPI
The Gaerttner LINAC Center at RPI uses a 60 MeV electron linear accelerator to produce short pulses of neutrons with duration of 5-5000 ns. The main research thrust at the Center is nuclear data for nuclear reactors and criticality safety applications. The Center includes several setups for time-of-flight measurements including neutron transmission, capture and scattering detectors, and a lead ...
متن کاملS - factors and reaction rates of ( p , n ) - reactions on 117 Sn , 118 Sn , 122 Sn , and 124
Astrophysical S-factors and reaction rates were derived from available cross sections of (p,n)-reactions on 117Sn, 118Sn, 122Sn, and 124Sn isotopes at incident proton energies up to 9MeV. The statistical theory predictions of the observable quantities are ∼2 times smaller at near threshold energies and have better agreement at higher energies. A large number of nuclear data primarily concerning...
متن کاملDesign and Simulation of Photoneutron Source by MCNPX Monte Carlo Code for Boron Neutron Capture Therapy
Introduction Electron linear accelerator (LINAC) can be used for neutron production in Boron Neutron Capture Therapy (BNCT). BNCT is an external radiotherapeutic method for the treatment of some cancers. In this study, Varian 2300 C/D LINAC was simulated as an electron accelerator-based photoneutron source to provide a suitable neutron flux for BNCT. Materials and Methods Photoneutron sources w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2005