Measuring ethanol in blood and breath for legal purposes: variability between laboratories and between breath-test instruments.
نویسندگان
چکیده
We determined the concentrations of ethanol in nearly simultaneous specimens of venous blood (BAC) and end-expired breath (BrAC) after healthy volunteers drank moderate amounts of alcohol. BAC was measured at two laboratories and BrAC was analyzed with two instruments (Intoxilyzer 5000) from the same manufacturer. The mean difference in BAC between laboratories was 0.0105 mg/g (SD 0.0219); 95% of the differences ranged from -0.0333 to 0.0543 mg/g. The mean difference in BrAC between instruments was 0.0153 mg/L (SD 0.0136), and 95% of the differences ranged from -0.0119 to 0.0425 mg/L. The coefficient of variation (CV) between laboratories was 2.9% compared with 4.5% between breath-test instruments. Venous BAC (y) and BrAC (x) were highly correlated (r = 0.978). However, when the Intoxilyzer instruments indicated that BrAC had reached zero, the actual BAC was 0.135 mg/g, according to the average forensic laboratory reports. The Intoxilyzer 5000 breath analyzers used in this study seem to have a constant analytical bias.
منابع مشابه
Measuring Alcohol in Blood and Breath for Forensic Purposes - A Historical Review.
This review concerns important events and trends in the evolution of chemical tests for alcohol intoxication on two continents; Europe and North America. In particular, the pioneer workers in this field and their major contributions to forensic alcohol analysis are emphasized. Quantitative methods for the determination of alcohol in blood, breath, and urine appeared early in the twentieth centu...
متن کاملMedicolegal Alcohol Determination - Blood- or Breath-Alcohol Concentration?
Measuring the concentration of alcohol in body fluids represents a large part of the workload at forensic science and toxicology laboratories. In traffic-law enforcement, breath-alcohol testing is used worldwide for roadside screening and for evidential purposes. Many jurisdictions have adopted per se laws which make it a crime to drive with a blood- or breath-alcohol concentration above a pres...
متن کاملMedicolegal alcohol determination: variability of the blood- to breath-alcohol ratio and its effect on reported breath-alcohol concentrations.
There is substantial agreement among scientists that the variability of a person's blood- to breath-alcohol ratio contributes significantly to the experimental error in results from breath-alcohol analysis. Some have argued that the need to correct for this source of error can be eliminated by reporting breath test results in units of breath-alcohol concentration rather than blood-alcohol conce...
متن کاملA New Methodfor the Rapid A nalysis of Ethanol in Breath, Blood, Urine and Saliva Using the A Icolmeter Evidential Instrument
The introduction of legislation to control driving under the influence o f alcohol has led to the development and use of a number of instrumental methods for measuring the concen tration of alcohol in body fluids.11 Standard methods for blood and urine analysis, based mainly on gas chromatography, are in common use and under laboratory conditions can give results with standard deviations of be...
متن کاملTesting for driving under the influence of ethanol: misleading results caused by ether.
The correlation between driving under the influence of alcohol (DUI), medication, or illicit drugs and the occurrence of traffic accidents is well recognized. Threshold concentrations for intoxicating substances in a driver's blood, such as legal and illegal drugs and organic solvents, have not yet been regulated. The statuary limits of blood-alcohol concentration, however, are well defined in ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 38 5 شماره
صفحات -
تاریخ انتشار 1992