On-line multichannel Raman spectroscopic detection system for capillary zone electrophoresis.
نویسندگان
چکیده
An on-line multichannel Raman spectroscopic detection system for capillary zone electrophoresis using a charge-coupled device as the detector is described. Resonant, near-resonant and non-resonant excitation Raman spectroscopies are employed. The 400 cm-1 spectral window provides adequate information to identify resolved and unresolved compounds. The use of analyte velocity reduction to allow increased data acquisition times is described. With near-resonant enhancement, the technique is shown to allow detection of 500 attomoles of methyl orange from a 5-nl injection volume, corresponding to 1 x 10(-7) M.
منابع مشابه
Ultrasensitive online SERS detection of structural isomers separated by capillary zone electrophoresis.
A mixture of structural isomers was separated and identified at nanomolar concentrations (∼100,000 molecules) by incorporating capillary zone electrophoresis (CZE) with a sheath flow surface-enhanced Raman scattering (SERS) detector. Baseline resolution was obtained from three structural isomers of rhodamine using a planar silver SERS substrate, demonstrating the utility of this approach for tr...
متن کاملOnline SERS detection and characterization of eight biologically-active peptides separated by capillary zone electrophoresis.
There is a need for low cost, sensitive and chemical specific detectors for routine characterization of biomolecules. In this study, we utilize sheath-flow surface-enhanced Raman scattering (SERS) to analyze a mixture of eight biologically-active peptides separated by capillary zone electrophoresis (CZE). Analysis of the SERS electropherogram resulting from online detection resolves the charact...
متن کاملField programming to achieve uniform sensitivity for on-line detection in electrophoresis.
Under constant applied electric field, an analyte band traverses an on-line detection zone in an electrophoretic separation at a velocity inversely proportional to the detection time. Because analyte bands migrate with different velocities, the sensitivity of the detection system to different species can vary significantly. One approach for overcoming this problem is to change the applied elect...
متن کاملOnline SERS detection of the 20 proteinogenic L-amino acids separated by capillary zone electrophoresis.
A sheath-flow surface-enhanced Raman scattering (SERS) detector is demonstrated to provide chemical information enabling identification of the 20 proteinogenic L-amino acids separated by capillary zone electrophoresis (CZE). Amino acids were used to illustrate the chemical specificity of SERS detection from structurally related molecules. Analysis of the SERS electropherograms obtained from the...
متن کاملEffect of Capillary Rinsing Protocol on the Reproducibility of Separation in Capillary Electrophoresis with Indirect UV Detection
Capillary electrophoresis (CE) with indirect UV detection is an interesting analytical method for the analysis of drugs and pharmaceuticals. Good and reproducible capillary quality is needed to develop robust methods and to facilitate method transfer in CE. It is widely accepted that preconditioning procedures are indispensable in capillary electrophoresis in order to achieve reproducibility of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of chromatography
دوره 540 1-2 شماره
صفحات -
تاریخ انتشار 1991