Comparison of qualitative (COBAS AMPLICOR HCV 2.0 versus VERSANT HCV RNA) and quantitative (COBAS AMPLICOR HCV monitor 2.0 versus VERSANT HCV RNA 3.0) assays for hepatitis C virus (HCV) RNA detection and quantification: impact on diagnosis and treatment of HCV infections.
نویسندگان
چکیده
Quantitative measurements of serum hepatitis C virus (HCV) RNA are becoming increasingly important in the management of HCV-infected patients. Here we compared two quantitative assays, the COBAS AMPLICOR HCV Monitor 2.0 assay (Roche Diagnostics) and the branched DNA-based VERSANT HCV RNA 3.0 assay (Bayer Diagnostics) for HCV RNA measurement in 344 samples derived from 120 patients with chronic genotype 1 HCV infection. The overall concordance between the results of the two tests was 95%, and the HCV RNA titers within the dynamic ranges of the assays correlated very well (r2=0.86). Furthermore, both tests performed equally well in determining an early viral response at week 1 or 4 during antiviral therapy. We also compared two qualitative HCV RNA detection assays: the COBAS AMPLICOR HCV 2.0 assay versus the transcription-mediated amplification (TMA)-based VERSANT HCV RNA qualitative assay. Stored samples from sustained responders to interferon-ribavirin therapy were retested by the HCV TMA assay and were found to contain no detectable HCV RNA, demonstrating complete concordance between the results of PCR and TMA. However, HCV RNA was detected by the TMA assay in end-of-treatment (ETR) samples from 33% of patients with relapses who were HCV RNA negative according to the COBAS AMPLICOR assay. This observation suggests that a TMA assay can lead to a more correct definition of the ETR response.
منابع مشابه
Assessment of early virological response to antiviral therapy by comparing four assays for HCV RNA quantitation using the international unit standard: implications for clinical management of patients with chronic hepatitis C virus infection.
WHO International Standards for nucleic acid tests are used widely to compare the different assays used in HCV RNA quantitation. The aim of the study was to assess the impact of the international unit standard for measuring HCV RNA in the management of patients with chronic hepatitis C virus (HCV) infection. Twenty-seven naïve patients infected chronically by HCV were treated with ribavirin plu...
متن کاملEvaluation of the COBAS TaqMan HCV test with automated sample processing using the MagNA pure LC instrument.
The COBAS TaqMan HCV Test (TaqMan HCV; Roche Molecular Systems Inc., Branchburg, N.J.) for hepatitis C virus (HCV) performed on the COBAS TaqMan 48 Analyzer (Roche Molecular Systems) currently relies on a manual sample processing method. Implementation of an automated sample processing method would facilitate the clinical use of this test. In this study, we evaluated the performance characteris...
متن کاملAssessment of viral loads in patients with chronic hepatitis C with AMPLICOR HCV MONITOR version 1.0, COBAS HCV MONITOR version 2.0, and QUANTIPLEX HCV RNA version 2.0 assays.
The correlation between response to antiviral therapy and pretreatment viral load in patients with chronic hepatitis C has prompted the development of quantitative assays to measure viral load. The aim of our study was to assess the clinical relevance of the newly developed semiautomated PCR system COBAS HCV MONITOR version 2.0 in comparison with (i) the AMPLICOR HCV MONITOR version 1.0 assay, ...
متن کاملPerformance of the New Bayer VERSANT HCV RNA 3.0 assay for quantitation of hepatitis C virus RNA in plasma and serum: conversion to international units and comparison with the Roche COBAS Amplicor HCV Monitor, Version 2.0, assay.
We have evaluated the VERSANT HCV RNA 3.0. Assay (HCV 3.0 bDNA assay) (Bayer Diagnostics, Berkeley, Calif.), which is an improved signal amplification procedure for the HCV 2.0 bDNA assay for the quantitation of hepatitis C virus (HCV) RNA in serum or plasma of HCV-infected individuals. The HCV 3.0 bDNA assay has a linear dynamic range of 2.5 x 10(3) to 4.0 x 10(7) HCV RNA copies per ml (c/ml)....
متن کاملClinical evaluation of the automated COBAS AMPLICOR HCV MONITOR test version 2.0 for quantifying serum hepatitis C virus RNA and comparison to the quantiplex HCV version 2.0 test.
A second-generation hepatitis C virus (HCV) quantitative assay (COBAS AMPLICOR HCV MONITOR Test, version 2.0; COBAS HCM-2) has been developed, with the intention of achieving equivalent quantification of all HCV genotypes and improving assay performance. To evaluate the clinical performance of COBAS HCM-2 and its utility in predicting the response to alpha interferon treatment, sera from 215 ch...
متن کاملذخیره در منابع من