Novel parameter estimation methods for 11C-acetate dual-input liver model with dynamic PET.
نویسندگان
چکیده
The successful investigation of 11C-acetate in positron emission tomography (PET) imaging for marking hepatocellular carcinoma (HCC) has been validated by both clinical and quantitative modeling studies. In the previous quantitative studies, all the individual model parameters were estimated by the weighted nonlinear least squares (NLS) algorithm. However, five parameters need to be estimated simultaneously, therefore, the computational time-complexity is high and some estimates are not quite reliable, which limits its application in clinical environment. In addition, liver system modeling with dual-input function is very different from the widespread single-input system modeling. Therefore, most of the currently developed estimation techniques are not applicable. In this paper, two parameter estimation techniques: graphed NLS (GNLS) and graphed dual-input generalized linear least squares (GDGLLS) algorithms were presented for 11C-acetate dual-input liver model. Clinical and simulated data were utilized to test the proposed algorithms by a systematic statistical analysis. Compared to NLS fitting, these two novel methods achieve better estimation reliability and are computationally efficient, and they are extremely powerful for the estimation of the two potential HCC indicators: local hepatic metabolic rate-constant of acetate and relative portal venous contribution to the hepatic blood flow.
منابع مشابه
Tracer kinetic modeling of 11C-acetate applied in the liver with positron emission tomography.
It is well known that 40%-50% of hepatocellular carcinoma (HCC) do not show increased 18F-fluorodeoxyglucose (FDG) uptake. Recent research studies have demonstrated that 11C-acetate may be a complementary tracer to FDG in positron emission tomography (PET) imaging of HCC in the liver. Quantitative dynamic modeling is, therefore, conducted to evaluate the kinetic characteristics of this tracer i...
متن کاملKinetic Analysis of Dynamic 11C-Acetate PET/CT Imaging as a Potential Method for Differentiation of Hepatocellular Carcinoma and Benign Liver Lesions
OBJECTIVE The kinetic analysis of (11)C-acetate PET provides more information than routine one time-point static imaging. This study aims to investigate the potential of dynamic (11)C-acetate hepatic PET imaging to improve the diagnosis of hepatocellular carcinoma (HCC) and benign liver lesions by using compartmental kinetic modeling and discriminant analysis. METHODS Twenty-two patients were...
متن کاملApplication of Dual Phase Imaging of 11C-Acetate Positron Emission Tomography on Differential Diagnosis of Small Hepatic Lesions
OBJECTIVE Previously we observed that dual phase 11C-acetate positron emission tomography (AC-PET) could be employed for differential diagnosis of liver malignancies. In this study, we prospectively evaluated the effect of dual phase AC-PET on differential diagnosis of primary hepatic lesions of 1-3 cm in size. METHODS 33 patients having primary hepatic lesions with size of 1-3 cm in diameter...
متن کاملMultiparametric [11C]Acetate positron emission tomography-magnetic resonance imaging in the assessment and staging of prostate cancer
BACKGROUND The aim of this study was to evaluate whether MP [11C]Acetate PET-MRI enables an accurate differentiation of benign and malignant prostate tumors as well as local and distant staging. MATERIALS AND METHODS Fifty-six consecutive patients fulfilling the following criteria were included in this IRB-approved prospective study: elevated PSA levels or suspicious findings at digital recta...
متن کاملMinimally invasive method of determining blood input function from PET images in rodents.
UNLABELLED For cardiovascular research on rodents, small-animal PET has limitations because of the inherent spatial resolution of the system and because of cardiac motion. A factor analysis (FA) technique for extracting the blood input function and myocardial time-activity curve from dynamic small-animal PET images of the rodent heart has been implemented to overcome these limitations. METHOD...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- IEEE transactions on bio-medical engineering
دوره 53 5 شماره
صفحات -
تاریخ انتشار 2006