Determination of cocaine and metabolites in hair by column-switching LC-MS-MS analysis.
نویسندگان
چکیده
A method for rapid, selective, and robust determination of cocaine (CO) and metabolites in 5-mg hair samples was developed and fully validated using a column-switching liquid chromatography-tandem mass spectrometry system (LC-MS-MS). Hair samples were decontaminated, segmented, incubated overnight in diluted HCl, and centrifuged, and the diluted (1:10 with distilled water) extracts were analyzed in positive ionization mode monitoring two reactions per analyte. Quantifier transitions were: m/z 304.2→182.2 for CO, m/z 290.1→168.1 for benzoylecgonine (BE), and m/z 318.2→196.2 for cocaethylene (CE). The lower limit of quantification (LLOQ) was set at 0.05 ng/mg for CO and CE, and 0.012 ng/mg for BE. Imprecision and inaccuracy at LLOQ were lower than 20 % for all analytes. Linearity ranged between 0.05 and 50.0 ng/mg for CO and CE and 0.012 and 12.50 ng/mg for BE. Selectivity, matrix effect, process efficiency, recovery, carryover, cross talk, and autosampler stability were also evaluated during validation. Eighteen real hair samples and five samples from a commercial proficiency testing program were comparatively examined with the proposed multidimensional chromatography coupled with tandem mass spectrometry procedure and our reference gas chromatography coupled to mass spectrometry (GC-MS) method. Compared with our reference GC-MS method, column-switching technique and the high sensitivity of the tandem mass spectrometry detection system allowed to significantly reduce sample amount (×10) with increased sensitivity (×2) and sample throughput (×4), to simplify sample preparation, and to avoid that interfering compounds and ions impaired the ionization and detection of the analytes and deteriorate the performance of the ion source.
منابع مشابه
Simultaneous quantification of opiates, cocaine, and metabolites in hair by LC-APCI-MS/MS.
A quantitative LC-APCI-MS/MS method for simultaneous measurement of opiates, cocaine, and metabolites in hair was developed and validated. Cocaine and opiates were extracted from pulverized hair via sonication in methanol at 37 degrees C for 3 h. Samples were cleaned up using solid-phase extraction. LC separation was achieved in 20 min with identification and quantification by selected reaction...
متن کاملBioanalytical methods for the determination of cocaine and metabolites in human biological samples.
Determination of cocaine and its metabolites in biological specimens is of great importance, not only in clinical and forensic toxicology, but also in workplace drug testing. These compounds are normally screened for using sensitive immunological methods. However, screening methods are unspecific and, therefore, the posterior confirmation of presumably positive samples by a specific technique i...
متن کاملDetermination of Phthalate Metabolites in Human Serum and Urine as Biomarkers for Phthalate Exposure Using Column-Switching LC-MS/MS
OBJECTIVES Although phthalates like dibutyl phthalate (DBP) and di-2-ethylhexyl phthalate (DEHP) are commonly used as plasticizers and their metabolites are especially suspected of reproductive toxicity, little is known about occupational exposure to those phthalates. The aim of this study was to assess the utility of measuring the metabolite concentrations of DBP and DEHP in serum and urine sa...
متن کاملDetermination of methamphetamine and its metabolites incorporated in hair by column-switching liquid chromatography-mass spectrometry.
An automated column-switching liquid chromatographic-electrospray ionization-mass spectrometric (LC-ESI-MS) method has been established for the determination of methamphetamine (MA) and its metabolites, amphetamine (AP), and p-hydroxymethamphetamine (p-OH-MA) in hair. The combination of an N-vinylacetamide-containing hydrophilic polymer online extraction column, an SCX semi-micro LC column, and...
متن کاملDetermination of Cocaine and Metabolites in Urine Using Electrospray LC/MS
A rapid, simple, and sensitive electrospray LC/MS method has been developed for the quantitative analysis of cocaine and benzoylecgonine in urine using electrospray with the Agilent 1100 LC/MSD system. Urine samples were extracted using solid phase extraction cartridges, and the drug and metabolite were analyzed without derivatization using an isocratic separation and selected ion monitoring (S...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Analytical and bioanalytical chemistry
دوره 405 19 شماره
صفحات -
تاریخ انتشار 2013