Determination of inorganic phosphorus in serum: Evaluation of three methods applied to the Technicon RA-1000 analyzer

نویسندگان

  • L. Rubino
  • V. Catapano
  • G. Guerra
چکیده

We have evaluated three analytical methods for determining inorganic phosphorus in serum applied to the Technicon RA-I000 analyzer: a fully enzymatic colorimetric method based on the specific system purine nucleoside phosphorylase/xanthine oxidase coupled to an indicator colorimetric reaction similar to the Trinder reaction; a chemical method involving the direct UV measurement of the phosphomolybdate complex; and a chemical method with reduction of the phosphomolybdate complex to molybdenum blue. Experiments were performed to assess within-run and between-day precision, linearity, interference and correlation. The best performance characteristics were shown by the enzymatic colorimetric method and the phosphomolybdate UV method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Chemical and clinical evaluation of the random access analyzer "RA-1000".

In the RA-1000, a random-access discrete analyzer, an inert fluorocarbon fluid is used to prevent interaction and carryover. Production-model instruments were evaluated in two laboratories with respect to determination of glucose, creatinine, total protein, inorganic phosphorus, cholesterol, alkaline phosphatase, lactate dehydrogenase, creatine kinase, gamma-glutamyltransferase, and aspartate a...

متن کامل

Evaluation of Kjeldahl Digestion Method

The evaluation of the Kjeldahl digestion method was investigated by comparing measured values of total nitrogen, phosphorus and potassium using three salt and catalyst mixture in Standard Kjeldahl digestion method and Salicylic acid Modification method with certified values of plant material as well as comparison was made for determination of total nitrogen from steam distillation method verses...

متن کامل

An evaluation of the Technicon RA-1000 random-access analyzer.

We evaluated the Technicon RA-1000 analyzer, with emphasis on its potential for user-defined method development. Optical linearity and sample pipetting linearity were good. The reagent pipetting system delivered slightly less than the nominal amount, owing to the volumetric effect of added mixing bubbles. Carryover of aqueous solutions was negligible. The instrument had good adaptability for us...

متن کامل

Determinations of immunoglobulins G, A, and M in the Technicon RA-1000.

We evaluated the Technicon RA-1000 "Random Access" analyzer for the measurements of immunoglobulins G, A, and M in serum by turbidimetry. For various concentrations of serum pools the total CV ranged from 3.0 to 4.5% for IgG, from 3.1 to 3.2% for IgA, and from 4.8 to 5.4% for IgM. The linearity of the standard curves was good in the clinically useful ranges. Results for patients' samples correl...

متن کامل

Automated determination of urinary Na+, K+, chloride, inorganic phosphate, urea, and creatinine without sample dilution, with the "RA-XT".

We describe how concentrations of chloride, urea, inorganic phosphate, and creatinine in urine can be measured directly, without manual sample dilution, in a discrete analyzer (the Technicon "RA-XT"). These methods were accurate for concentrations of chloride up to 280 mmol/L, urea up to 500 mmol/L, inorganic phosphate up to 50 mmol/L, and creatinine up to 30 mmol/L. CVs are less than 3% nd res...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of Automatic Chemistry

دوره 11  شماره 

صفحات  -

تاریخ انتشار 1989