Ultrasound biomicroscopic measurement of anterior chamber biometry between before and after pupil dilation in children.
نویسندگان
چکیده
PURPOSE To evaluate anterior chamber biometry of the eyes of normal children using ultrasound biomicroscopy (UBM) and to evaluate the differences in biometry between children and adults, and before and after pupil dilation in children. METHODS Anterior chamber depth (ACD) and trabecular-iris angle (TIA) were measured in 94 normal children and 15 normal adults using UBM. Before and after pupil dilation were measured in 42 children with emmetropic and hyperopic eyes. RESULTS In 66 emmetropic children, ACD and TIA were 2.93+/-0.18 mm and 34.42+/-4.02 degrees, respectively. In 28 hyperopic children, ACD and TIA were 2.92+/-0.21 mm and 35.05+/-4.42 degrees, respectively. There was no significant difference in anterior chamber biometry associated with the refraction. ACD did not differ between children and adults, but TIA in children was wider than in adults. There was no significant difference in ACD or TIA before versus after pupil dilation in any case. CONCLUSIONS Anterior chamber biometry in children showed no differences before and after pupil dilation. Also, there was no difference in ACD of children as compared to adults; however, TIA in children was significantly wider than in adults.
منابع مشابه
Changes in intraocular pressure after pharmacologic pupil dilation
BACKGROUND Intraocular pressure (IOP) may vary according to the change of ocular conditions. In this study, we want to assess the effect and mechanism of pupil dilation on IOP in normal subjects. METHODS We prospectively evaluated 32 eyes of 32 patients (age; 61.7±8.2 years) with normal open angles under diurnal IOP. IOP was measured every two hours from 9 AM to 11 PM for one day to establish...
متن کاملMeasurement of aqueous humor flow by fluorophotometry in the presence of a dilated pupil.
PURPOSE To determine by means of fluorophotometry whether pharmacologic dilation of the pupil can interfere with the measurement of aqueous flow. METHODS Ten normal human volunteers underwent dilation with tropicamide, phenylephrine, and a combination of the two drugs. Before and after dilation, the rate of aqueous flow was measured by the rate of disappearance of fluorescein from the cornea ...
متن کاملUltrasound biomicroscopic analysis of pseudophakic pupillary block glaucoma induced by Soemmering's ring.
AIM To perform ultrasound biomicroscopic analysis of pseudophakic pupillary block glaucoma induced by lens capsule and a Soemmering's ring and its resolution, and to elucidate the pathophysiology of this glaucoma. METHODS A woman with pseudophakic pupillary block glaucoma underwent successful neodymium:YAG (Nd:YAG) laser photodisruption of the lens capsule through a laser iridotomised colobom...
متن کاملCentral corneal thickness and anterior chamber depth measurement by Sirius® Scheimpflug tomography and ultrasound
BACKGROUND The purpose of this study was to compare the accuracy of the new Sirius(®) Scheimpflug anterior segment examination device for measurement of central corneal thickness (CCT) and anterior chamber depth (ACD) with that of CCT measurements obtained by ultrasound pachymetry and ACD measurements obtained by ultrasound biometry, respectively. METHODS CCT and ACD was measured in 50 right ...
متن کاملEffect of pupillary dilation on Haigis formula-calculated intraocular lens power measurement by using optical biometry
PURPOSE The purpose of this study was to evaluate the effect of pupillary dilation on the Haigis formula-calculated intraocular lens (IOL) power and ocular biometry measurements by using IOLMaster(®). METHODS A prospective study was performed for biometry measurements of 373 eyes of 192 healthy subjects using the IOLMaster at the outpatient department of King Chulalongkorn Memorial Hospital f...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- European journal of ophthalmology
دوره 18 4 شماره
صفحات -
تاریخ انتشار 2008