Application of a vidicon spectrometer for simultaneous flame-emission analysis for sodium and potassium in serum.
نویسندگان
چکیده
We describe a unique new approach to analytical spectroscopy, which makes use of a silicon-target vidicon tube to rapidly and repetitively scan ultraviolet and visible spectra. We discuss the concept and characteristics of the vidicon spectrometer and illustrate its application to simultaneousdeterminationof sodium and potassium In serum by flame photometry. Average values of coefficients of variation for sodium and potassium are 1. 1% and 1.7%, respectIvely. Recoveries of sodium and patasslum added to sara were 99.5 % and 99.8 % , respectively. When the same burner and flame conditions were used with the vidicon spectrometer and a conventional flame photometer, deviations among results were well within ±3 mmol/liter for sodium and 0.2 mmoi/liter for potassium. A bias is observed for both elements when results obtained with an air-hydrogen flame are compared with results obtained with an air-propane flame. Our data illustrate that the vidicon spectrometer is a viable tool for both routine applications and basic studies of effects of flame conditions on two or more elements simultaneously.
منابع مشابه
Application of a vidicon spectrometer for simultaneous multicomponent drug determinations.
A rapid scanning vidicon spectrometer has been evaluated for the simultaneous determination of drugs in mixtures, without a separation step. Spectral data in the ultraviolet region are collected on-line with a small computer at repetition rates of 100 scans per second. Absorbance data at several wavelengths are processed by matrix equations to resolve them into the concentration of each compone...
متن کاملEvaluation of the total analytical error in the flame photometry method
Background and Objectives: For total analytical error, imprecision (SD) and bias, performance goals for laboratory tests have most often been developed. A total analytical error goal requires that the combination of errors from all sources (random and systematic errors) be within some acceptable limit. M...
متن کاملFlame photometric determination of electrolytes in tissue and of calcium in serum.
The convenience and accuracy of flame photometric methods for the determination of sodium and potassium in body tissues and fluids suggest the desirability of determining other cations such as calcium and magnesium in the same sample. While reliable procedures for the determination of sodium and potassium have been developed (1, 2), there are apparently no satisfactory flame spectrophotometric ...
متن کاملCalcium determination by flame photometry; methods for serum, urine, and other fluids.
The convenience and accuracy of flame photometric determinations of sodium and potassium in biological fluids (1, 2) have suggested the desirability of extending these advantages to determinations of calcium. Since calcium emission lines are much less intense than those of sodium and potassium (3), the samples of diluted serum (1: 50) customarily used for sodium and potassium determinat.ions ar...
متن کاملDetermination of major elements in fruit juices using the Agilent 4200 MP - AES with the Agilent 4107 Nitrogen Generator Application note
Major elements such as calcium, magnesium, sodium and potassium are essential nutrients in food and the routine monitoring of the levels of these elements in fruit juices is a common quality control process. Flame Atomic Absorption Spectroscopy (FAAS) is well suited to this application as it delivers the performance required for the analysis at a reasonable price. However, with the introduction...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 20 11 شماره
صفحات -