Storage effect of a pre-activated silane on the resin to ceramic bond.

نویسندگان

  • Tabassom Hooshmand
  • Richard van Noort
  • Alireza Keshvad
چکیده

OBJECTIVES The purpose of this study was to investigate the process of hydrolysis and chemical stability of a pre-activated silane solution stored for different periods of time. The tensile bond strength of resin composite to ceramic was also evaluated in order to determine the functional effectiveness after storage of the pre-activated silane solutions. METHODS Silane solutions using gamma-methacryloxypropyltrimethoxysilane (gamma-MPTS), acetic acid and ethanol were freshly prepared and kept for 15 min, 2 h, 24 h, 1 week, 1 month, 6 months, and 1 year. The solutions were analyzed using a 2000 Perkin-Elmer Fourier transform infrared (FT-IR) spectrophotometer. For the tensile bond strength test, Ni/Cr rods were prepared with ceramic facings polished to 1 microm. Five groups of ceramic surfaces (n = 60) were treated with the pre-activated silane solutions and bonded using a luting resin. The process used to prepare the surfaces prior to bonding consisted of removing unreacted silane by boiling water and then heat treatment. Each group was then subdivided into two groups (n = 30) and stored under two different storage conditions before subjecting to the tensile bond strength test; either (1) dry at room temperature for 24 h or (2) boiling water for 24 h. RESULTS FT-IR analysis showed that nearly complete hydrolysis of gamma-MPTS has occurred 24 h after mixing, followed more slowly by the formation of siloxane (Si-O-Si) oligomers. The bond strength test results showed that there was no statistically significant difference in the mean tensile bond strength for any of the groups either in dry condition or in boiling water (P > 0.05). The mode of failure for all groups was predominantly cohesive failure within the resin. The silane bond was also capable of resisting hydrolytic attack in boiling water for all the groups. SIGNIFICANCE From the results of this study it can be concluded that, when using an appropriate silane application technique, the adhesive effectiveness of a pre-activated silane solution based on gamma-MPTS, acetic acid and ethanol will not deteriorate when stored for up to 1 year at room temperature.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Shear Bond Strength of Silorane and Methacrylate-Based Composites to IPS Empress 2 Ceramic with Various Surface Treatments

Objectives: Treatment of chipped or fractured porcelain with composite resin is considered as an economic treatment for minor fractures in ceramics. The aim of this study was to evaluate the effect of different ceramic surface treatments on bond strength of methacrylate-based and silorane-based composite resin to IPS Empress 2. Methods: Sixty IPS Empress 2 ceramic discs were fabrica...

متن کامل

Silane and bonding of Resins to Ceramic

Silane and bonding of Resins to Ceramic Dr. K. Seyyedan* - Dr. M. Kalalipoor** - Dr. M. Javan***Assistant Professor of Fixed Prosthodontics Dept., Faculty of Dentistry, Shaheed Beheshti University of Medical Sciences. **Resident of Fixed Prosthodontics Dept., Faculty of Dentistry, Shaheed Beheshti University of Medical Sciences. Background and Aim: When bonding between two different dental mate...

متن کامل

Effect of Silane on Shear Bond Strength of Two Porcelain Repair Systems

Objectives: Ceramics have advantages such as optimal esthetics and biocompatibility. However, in the oral environment, they are subjected to high levels of stress due to masticatory forces, saliva, thermal changes and alterations of pH, which increase their risk of fracture. Since replacement of these restorations is costly and time-consuming, composite resin is often used for intraoral repair ...

متن کامل

The effect of different surface treatments on bond strength between leucite reinforced feldspathic ceramic and composite resin.

OBJECTIVES The aim of this study was to evaluate the effect of different surface treatments on the microtensile bond strength between a leucite reinforced glass-ceramic and composite resin. METHODS Leucite reinforced ceramic blocks (n=24) were constructed using the hot pressing technique. The blocks were assigned to 4 groups, which received the following surface treatments: G1: hydrofluoric (...

متن کامل

Silanization effect on microtensile bond strength of a self-adhesive luting material to a disilicate- based glass ceramic

Introduction: The rehabilitation of teeth by means of ceramic indirect restorations has been widely performed. Previous studies has shown the effectiveness of silane coupling agents on improving the bond strength of the adhesion of resin cements to ceramics; however, some studies question the use of silane. Objective: To evaluate the effect of silane application on the microtensile bond strengt...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Dental materials : official publication of the Academy of Dental Materials

دوره 20 7  شماره 

صفحات  -

تاریخ انتشار 2004