Preanalytical treatment of EDTA-anticoagulated blood to ensure stabilization of the mean platelet volume and component measured with the ADVIA counters.
نویسندگان
چکیده
The mean platelet component (MPC) parameter calculated by the ADVIA blood cell analyzers provides direct information on density, or granularity, of platelets and could become a useful biomarker to detect in vivo platelet activation. Unfortunately, it is largely affected by time and storage conditions in standard anticoagulants based on EDTA. The present study was designed to improve the stability of the MPC in blood specimens to facilitate a more standardized use in different laboratories. Blood from healthy controls was collected into EDTA plus additives, and stored at different conditions. MPC and the mean platelet volume (MPV) were assessed at 30 min and at 1, 3, 6 and 24hours after blood drawing on the ADVIA 2120 system. Flow cytometry was used to evaluate platelet-activation proteins. Ultrastructural morphology of platelets was assessed using electron microscopy. Storage in EDTA increased MPV, decreased MPC, reduced the number of alpha-granules, and induced changes in the phosphorylation patterns of platelet proteins. A solution based on EDTA containing wortmanin and tyrphostin (ED-WORTY), both inhibitors of signaling pathways, provided good stability for most of the parameters tested up to 6 hours at room temperature. Storage at lower temperatures produced more favorable results. ED-WORTY solutions preserved adequate morphology and had minimal influence on other parameters provided by the ADVIA 2120 system. Thus, the additives included in ED-WORTY may be useful for maintaining the stability of MPC for prolonged periods and to facilitate the transport and exchange of samples among institutions and laboratories.
منابع مشابه
Evaluation of the anticoagulants EDTA and citrate, theophylline, adenosine, and dipyridamole (CTAD) for assessing platelet activation on the ADVIA 120 hematology system.
BACKGROUND Monitoring of platelet activation by the ADVIA 120 Hematology System requires an anticoagulant and protocol that ensures that platelets are sphered and their activation status is not altered artifactually in vitro. METHODS Blood from healthy controls was collected into tripotassium EDTA; citrate, theophylline, adenosine, and dipyridamole (CTAD); or a combination of both (E/C) and s...
متن کاملEstimation of Platelet Counts and Other Hematological Parameters in Pseudothrombocytopenia Using Alternative Anticoagulant: Magnesium Sulfate
The platelet count, mean platelet volume, and other hematological parameters were compared in blood samples anticoagulated with MgSO4 and EDTA. A total of 15 samples were taken, and the platelet counts were observed to be significantly high in MgSO4-anticoagulated blood samples ranging from 53 × 103 to 499 × 103/μL, whereas in EDTA-anticoagulated blood samples, the counts ranged from 10 × 103 t...
متن کاملAlteration of Platelet Indices in Young Children with Acute Pyelonephritis
Background Platelets have an important contribution in pathogenesis of different infectious and inflammatory disorders. This study was performed to identify the diagnostic value of platelet count (PLT), and platelet indices in children with acute pyelonephritis (APN). Materials and Methods In a cross sectional case control s...
متن کاملReference Intervals for Platelet Parameters in Korean Adults Using ADVIA 2120
Analysis of thrombopoiesis is important in evaluating hematologic and non-hematologic diseases. Recent improvements in automated blood cell analyzers allow measurement of several platelet parameters, providing additional information on the underlying mechanisms of thrombocytosis and thrombocytopenia. The ADVIA 2120 Hematology System (Siemens AG, Eschborn, Germany) distinguishes platelets by a t...
متن کاملPseudothrombocytopenia--a cautionary tale.
Multichannel electronic cell counters are now in widespread use in haematology laboratories. Platelet counts are given routinely by many instruments and low platelet counts generate much further investigation. A falsely low platelet count may expose the patient to unnecessary and expensive investigation and treatment, and we report two illustrative cases. The platelet counts were performed on b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Thrombosis research
دوره 126 1 شماره
صفحات -
تاریخ انتشار 2010