The control of new prosthetic implants.

نویسندگان

  • A M Collier
  • S Patil
چکیده

The recent well-publicised problem of early failure of the 3M Capital Hip has led both the public and orthopaedic surgeons to question the effectiveness of existing controls in the UK which govern the introduction of new pros-theses for joint replacement. It has also resulted in renewed demands for a National Hip Register, similar to those successfully developed by Sweden and Norway, 1,2 to provide better long-term surveillance of different designs of implant. The Scandinavian Registers have certainly been successful in drawing attention to poorly performing prostheses, such as the Christiansen Hip, 3 as well as identifying problems in the materials used for joint replacement, as with 'Boneloc' cement. 4,5 Their long-term data confirm that selection of the prosthesis is the factor which has the greatest influence on long-term survivor-ship. The problem of early failure of the implant is not new, nor is it confined to Europe, since major difficulties have also been reported recently from North America in a number of roughened femoral stems used with acrylic 'precoat' technology. 6,7 Should we be able to predict these types of failure? To do so requires a better understanding of the mechanism of early breakdown, which must be different from the well-recognised late failure resulting from the production of prosthetic wear particles characterised by the formation of excessive granulation tissue and osteolysis. The Capital Hip, which was introduced by the 3M Company in 1991, was marketed as a femoral stem with a shape similar, but not identical, to the current version of the Charnley stem. The emphasis at the time of its introduction was on the low cost of the prosthesis and the outstanding performance of the existing hip replacement based on the Charnley principles. The femoral implant was manufactured in two materials; a modular design with a titanium-alloy stem and either a chrome-cobalt or titanium-nitride head, and a monobloc in stainless steel. A number of stem shapes were available for each of these. Modularity allowed the use of heads of various sizes and different materials. The titanium alloy used for the stem was chosen to give the advantages of a lower modulus of elasticity, better biocompatibility, and reduced tissue toxicity. The stem design featured round corners proximally to ensure a more uniform load transfer to the supporting cement, a slightly roughened matt surface texture, and an acrylic centraliser at its tip. It was inserted using specially designed instruments with broaches and …

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Full mouth rehabilitation with fixed prostheses in the case of unaligned and malpositioned implants: clinical report

Full mouth rehabilitation with fixed implant supported prostheses is one of the challenging treatments, because important factors in aesthetic and function should be considered. Implants' alignments and locations should be planned before the insertion unless the improper inclination and location of implants would lead to difficulties in patient's comfort, oral hygiene problem and inability to r...

متن کامل

Immediate loading in dental implants ( A literature review )

Immediate loading in dental implants ( A literature review ) Dr. Seyedan K.,1 Dr. Hafezeqoran A.,2 Dr. Sazgara H.3 1Assistant Professor, Department of Prosthodentists,Dental School Shahid Beheshti University of Medical Sciences,Tehran, Iran.2Dentist, Post Graduate Student, Department of Prosthodontics, Dental School, Shahid Beheshti University of Medical Sciences, Tehran-Iran.3Associate Profess...

متن کامل

Determining the prevalence of peri-implantitis in patients one year after prosthetic loading in Khorramabad in 2021

Background and Aims: Although dental implants have become a successful and predictable ong-term treatment for patients, not all implant treatments are necessarily successful and pre-implant diseases are spreading. The aim of this study was to determine the prevalence of peri-implantitis in patients one year after prosthetic loading in Khorramabad in 2021. Materials and Methods: In this cross-s...

متن کامل

Bone density study of the proximal femur after hip arthroplasty with porous-coated implants

Progressive loss of bone mineral density around the femora! component of total hip replacement continues to pose a threat to long term prosthetic survival. A linear study was undertaken to measure bone mineral density on a monthly basis following total hip arthroplasty in 11 male patients. The opposite femur was used as the control measurement. Bone mineral density was unchanged at two mo...

متن کامل

Prosthetic Rehabilitation of Nasal Defect: A Case Report

Abstract Facial defects not only impact on the function and quality of life but also affect the psychological well-being and social behavior of patients. A nasal prosthesis can re-establish the esthetics and anatomical contour in patients with mid-facial defects, often more effectively than surgical reconstruction. For successful results, many factors such as retention, texture, color match ...

متن کامل

Clinical evaluation of soft tissue surrounding prosthesis supported by implants

Clinical evaluation of soft tissue surrounding prosthesis supported by implants Dr. A. Fazel* - Dr. M. Rismanchian** *- Associate Professor of Prosthodontics Dept. - Faculty of Dentistry - Tehran University of Medical Sciences. **- Assistant Professor of Prosthodontics Dept. – Faculty of Dentistry - Isfahan University of Medical Sciences. Background and Aim: Nowadays, reconstruction and replace...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 80 6  شماره 

صفحات  -

تاریخ انتشار 1998