Evaluation of the alkaline haematin D-575 method for haemoglobin estimation in east Africa.
نویسندگان
چکیده
In many health facilities in east Africa, haemoglobin estimation is performed using visual colour comparison methods. Efforts to establish colorimetric methods face numerous constraints, including the unavailability of standards for quality control. In contrast, the alkaline haematin D-575 method for haemoglobin estimation is a colorimetric method that uses primary standards prepared from pure, crystalline chlorohaemin. There is no significant difference in the accuracy of the alkaline haematin D-575 method and that of the reference haemiglobincyanide method (P > 0.05), and the response of the alkaline haematin D-575 method is linear for serially diluted blood samples over the haemoglobin concentration range 19.6-3.3 g/dl (r = 0.994, y = 1.01 x - 0.3). The method has a precision of +/-0.3 g/dl (coefficient of variation = (1.8%) for whole blood, and is suitable for use with fixed-wavelength haemglobinometers (lambda = 565 nm) or with colorimeters at lambda = 580 nm. Stable quality control standards could be prepared at provincial, zonal, or reference laboratories and distributed regularly to outlying laboratories.
منابع مشابه
Evaluation of the alkaline haematin D-575 method for haemoglobin estimation in east
In many health facilities in east Africa, haemoglobin estimation is performed using visual colour comparison methods. Efforts to establish colorimetric methods face numerous constraints, including the unavailability of standards for quality control. In contrast, the alkaline haematin D-575 method for haemoglobin estimation is a colorimetric method that uses primary standards prepared from pure,...
متن کاملObservations on the alkaline haematin/detergent complex proposed for measuring haemoglobin concentration.
The "alkaline haematin D-575" method for determining haemoglobin, described by Zander et al. [1984) Clin. Chim. Acta 136, 83-93) was tested. Claims that different non-ionic detergents in the reagent result in identical values for the haemoglobin concentration being measured could not be verified. It could also not be verified that a stable end-product with unique spectral characteristics is alw...
متن کاملInternational collaborative assessment study of the AHD575 method for the measurement of blood haemoglobin.
Accurate, economical methods for haemoglobin determination by laboratories in countries with limited resources are not available. This report provides the results of an international collaborative study evaluating the alkaline haematin detergent (AHD575) method as a reference method for laboratory services with limited resources. The study included 6 laboratories; 3 in East Mediterranean countr...
متن کاملObservations on the binding of haemoglobin and haematin by serum proteins in the rabbit. rat and guinea pig.
When haemoglobin is added to human plasma, it is bound through the globin portion of the molecule to an C2-globulin (Jayle, Boussier & Badin, 1952; Nyman, 1959). It has also been suggested that in human sera haemoglobin combines with albumin (Neale, Aber & Northam, 1958) and with a Plglobulin (Neale et al. 1958; Tombs, 1960), but these complexes could not be found by Allison & ap Rees (1957), A...
متن کاملCclii. Some Observations on the Estimation of Muscle
N-UMEROUS observations in the past decade, culminating in the isolation of the crystalline material and the study of its properties by Theorell [1932; 1934, 1, 2, 3, 4] have established the identity of muscle haemoglobin. Attempts to estimate it, however, have for the most part been concerned with it less as a chemical identity than as that haemoglobin which remains behind after perfusing the t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Bulletin of the World Health Organization
دوره 72 6 شماره
صفحات -
تاریخ انتشار 1994