Characterization of Respiratory Conditions Using LabVIEW and Digital Spirometer

نویسندگان

  • S. Noorjannah Ibrahim
  • Abdul Malik
چکیده

Received Jan 6, 2018 Revised Mar 8, 2018 Accepted Mar 23, 2018 One of the effective ways to diagnose various respiratory diseases is using spirometry test. Good spirometer comes with excellent graphical user interface. Spirometer is used to measure lung parameters such as Forced Expiratory Volume in the first second and the sixth seconds (FEV1 and FEV6). This paper presents an algorithm with Graphical User Interface (GUI) for characterization of respiratory conditions using LabVIEW Software. The whole spirometry system consists of a breathing circuitry with pressure sensor and a data acquisition board (NI sbRIO FPGA board). Results obtained from three different volunteers with different health performances are also presented in this paper. The FEV1/FEV6 ratio of a healthy volunteer is 81.1%, an asthma volunteer is 72.04%, and suspected bronchitis volunteer is 33.4%. Based on these results, the unhealthy volunteers tend to have smaller value of FEV1 with lower area under the curve when compared to healthy volunteer.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

رابطه میزان کیفوز پشتی با ظرفیت های تنفسی

Objectives: Kyphosis is a common spinal abnormality. It is thought that kyphosis has an effect on respiratory system function. The purpose of this study was to investigate the relationship between thoracic kyphosis and respiratory capacities measurement by spirometer. Materials &Methods: This is a descriptive correlational design. A total of 20 males who are matched with age and body mass inde...

متن کامل

Variation in the rapid shallow breathing index associated with common measurement techniques and conditions.

BACKGROUND The rapid-shallow-breathing index (RSBI) is widely used to evaluate mechanically ventilated patients for weaning and extubation, but it is determined in different clinical centers in a variety of ways, under conditions that are not always comparable. We hypothesized that the value of RSBI may be significantly influenced by common variations in measurement conditions and technique. ...

متن کامل

A LabVIEW Platform for Preclinical Imaging Using Digital Subtraction Angiography and Micro-CT.

CT and digital subtraction angiography (DSA) are ubiquitous in the clinic. Their preclinical equivalents are valuable imaging methods for studying disease models and treatment. We have developed a dual source/detector X-ray imaging system that we have used for both micro-CT and DSA studies in rodents. The control of such a complex imaging system requires substantial software development for whi...

متن کامل

Could the Difference in Respiratory Muscle Power Explain Gender Variation in Lung Function?

Few studies have been done to explain gender difference in lung function and none was conclusive. This study questions whether there is a gender difference in respiratory muscle power and its correlation with the lung function values. The study included two groups of University students 25 males and 25 females matched for age, height and weight. They were of the same ethnic class, socioeconomic...

متن کامل

The accuracy of spirographic recording at high respiratory rates.

Spirometers were designed and used originally for the measurement of metabolic rate or such respiratory constants as vital capacity. Such measurements are made at low rates of respiration (up to about 40 breaths per minute) or with single inspiratory or expiratory efforts. There has been no reason to suspect the accuracy of records made under these conditions. Since Hermannsen (1933) first desc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2018