High temporal resolution aberrometry in a 50-eye population and implications for adaptive optics error budget.
نویسندگان
چکیده
We formed a database gathering the wavefront aberrations of 50 healthy eyes measured with an original custom-built Shack-Hartmann aberrometer at a temporal frequency of 236 Hz, with 22 lenslets across a 7-mm diameter pupil, for a duration of 20 s. With this database, we draw statistics on the spatial and temporal behavior of the dynamic aberrations of the eye. Dynamic aberrations were studied on a 5-mm diameter pupil and on a 3.4 s sequence between blinks. We noted that, on average, temporal wavefront variance exhibits a n-2 power-law with radial order n and temporal spectra follow a f-1.5 power-law with temporal frequency f. From these statistics, we then extract guidelines for designing an adaptive optics system. For instance, we show the residual wavefront error evolution as a function of the number of corrected modes and of the adaptive optics loop frame rate. In particular, we infer that adaptive optics performance rapidly increases with the loop frequency up to 50 Hz, with gain being more limited at higher rates.
منابع مشابه
Comparison of sorting algorithms to increase the range of Hartmann-Shack aberrometry.
Recently many software-based approaches have been suggested for improving the range and accuracy of Hartmann-Shack aberrometry. We compare the performance of four representative algorithms, with a focus on aberrometry for the human eye. Algorithms vary in complexity from the simplistic traditional approach to iterative spline extrapolation based on prior spot measurements. Range is assessed for...
متن کاملSimulating IOL designs using adaptive optics Validation of a new integrated aberrometry-topography system Comparing accommodating and asymmetric multifocal IOLs
With our background in clinical ophthalmic research, mainly of the anterior eye, Bausch and Lomb have asked us to produce an independent report of some of the interesting findings coming out of the research journals each month. As a busy practitioner, this should allow you to keep more up-to-date with cutting edge clinical research and allow you to locate the articles when you want to know more...
متن کاملCASE REPORT Benefit of Adaptive Optics Aberration Correction at Preferred Retinal Locus
Purpose. To investigate the effect of eccentric refractive correction and full aberration correction on both highand low-contrast grating resolution at the preferred retinal locus (PRL) of a single low-vision subject with a long-standing central scotoma. Methods. The subject was a 68-year-old women with bilateral absolute central scotoma due to Stargardt disease. She developed a single PRL loca...
متن کاملFusion of LST products of ASTER and MODIS Sensors Using STDFA Model
Land Surface Temperature (LST) is one of the most important physical and climatological crucial yet variable parameter in environmental phenomena studies such as, soil moisture conditions, urban heat island, vegetation health, fire risk for forest areas and heats effects on human’s health. These studies need to land surface temperature with high spatial and temporal resolution. Remote sensing ...
متن کاملAdaptive Spectral Separation Two Layer Coding with Error Concealment for Cell Loss Resilience
This paper addresses the issue of cell loss and its consequent effect on video quality in a packet video system, and examines possible compensative measures. In the system's enconder, adaptive spectral separation is used to develop a two-layer coding scheme comprising a high priority layer to carry essential video data and a low priority layer with data to enhance the video image. A two-step er...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Biomedical optics express
دوره 8 4 شماره
صفحات -
تاریخ انتشار 2017