The impact of model detail on power grid resilience measures

نویسندگان

  • S. Auer
  • K. Kleis
  • P. Schultz
  • J. Kurths
  • F. Hellmann
چکیده

Extreme events are a challenge to natural as well as manmade systems. For critical infrastructure like power grids, we need to understand their resilience against large disturbances. Recently, new measures of the resilience of dynamical systems have been developed in the complex system literature. Basin stability and survivability respectively assess the asymptotic and transient behavior of a system when subjected to arbitrary, localized but large perturbations in frequency and phase. To employ these methods that assess power grid resilience, we need to choose a certain model detail of the power grid. For the grid topology we considered the Scandinavian grid and an ensemble of power grids generated with a random growth model. So far the most popular model that has been studied is the classical swing equation model for the frequency response of generators and motors. In this paper we study a more sophisticated model of synchronous machines that also takes voltage dynamics into account, and compare it to the previously studied model. This model has been found to give an accurate picture of the long term evolution of synchronous machines in the engineering literature for post fault studies. We find evidence that some stable fix points of the swing equation become unstable when we add voltage dynamics. If this occurs the asymptotic behavior of the system can be dramatically altered, and basin stability estimates obtained with the swing equation can be dramatically wrong. We also find that the survivability does not change significantly when taking the voltage dynamics into account. Further, the limit cycle type asymptotic behaviour is strongly correlated with transient voltages that violate typical operational voltage bounds. Thus, transient voltage bounds are dominated by transient frequency bounds and play no large role for realistic parameters. a e-mail: [email protected] 610 The European Physical Journal Special Topics

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improving the resilience of active distribution networks by optimal charging/discharging management of electric vehicles in parking lots

In the event of a severe incident with a high impact and low probability of occurrence, distribution networks may be separated from upstream networks and several feeders may be disconnected simultaneously within the distribution networks. In such circumstances, to maximize the resilience of the distribution networks and to prevent long-term global outages, they are reconfigured and islanded to ...

متن کامل

Model Predictive Control of a BCDFIG With Active and Reactive Power Control Capability for Grid-Connected Applications

Recently, Brushless Cascaded Doubly Fed Induction Generator (BCDFIG) has been considered as an attractive choice for grid-connected applications due to its high controllability and reliability. In this paper, a Finite Control Set Model Predictive Control (FCS-MPC) method with active and reactive power control capability in grid-connected mode is proposed for controlling the BCDFIG in a way that...

متن کامل

Prioritizing Resilience Enhancement Measures for Electric Distribution Networks Against Hurricanes

In recent years, climate change and increasing occurrence rate of high-impact rare (HR) natural events such as hurricanes have made it difficult to supply uninterrupted power to end-user customers. The extensive geographic area of electric distribution networks, as the last ring of the energy supply chain in power systems, has increased the vulnerability of these networks against natural events...

متن کامل

Design of A Single-Phase Transformerless Grid-Connected PV Inverter ‎Considering Reduced Leakage Current and LVRT Grid Codes

A new single-phase transformerless grid-connected PV inverter is presented in this paper. Investigations in transformerless grid-connected PV inverters indicate the existence of the leakage current is directly related to the variable common-mode voltage (CMV), which is presented in detail. On the other hand, in recent years it has become mandatory for the transformerless grid-connected PV inver...

متن کامل

Weighting and prioritizing of indicators affecting resilience in the fire-induced emergencies in combined cycle power plant using fuzzy analytic hierarchy process

Abstract Background and Objective: Increasing the level of resilience is one of the approaches to reduce the consequences of fire. Resilience is one of the most important and practical concepts in crisis management that has been considered in recent years.The current study was aim to identify and prioritize of indicators affecting resilience in the event of fire-induced emergencies in combined...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016