Comparison of 2- and 3-Point Dixon Techniques in RF- and Readout-Shifted FSE Sequences

نویسندگان

  • H. K. Song
  • A. C. Wright
  • R. L. Wolf
  • F. W. Wehrli
چکیده

Introduction Different implementations of the Dixon technique (1) have been used to quantify fat and water in various parts of the human body. In most applications, the 3-point Dixon technique with Bo correction is preferred over simple suppression methods because of its robustness in the presence of Bo inhomogeneities (2). It is also superior to the saturation techniques from an SNR standpoint, offering an equivalent of 2-2.7 signal averages. More recently, a 2D FSE version of the Dixon technique has been described (3), where it was suggested that shifting the acquisition window may be preferred to shifting the RF pulses, in order to meet the CPMG criterion. Although generally less robust than the 3-point counterpart, the 2-point Dixon technique with phase unwrapping (4,5) has the advantage of shorter scan time, and with fewer acquisitions, can be less susceptible to misregistration artifacts in the fat/water component images. The purpose of this work is to compare the 2and 3-point Dixon techniques in both RFand readout (RO)-shifted versions of the 2D FSE sequence, and to evaluate the effects of transverse relaxation on measurement accuracy. Fat (proton density) fractions are compared in several regions of the calcaneus (heel bone), where T2* varies considerably (6).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fat Suppressed FSE Pelvic MR Imaging with Two New FSE Based Dixon Pulse Sequences: A Comparison of IDEAL FSE and FSE Triple Echo Dixon

Background: Fat suppressed FSE T2-weighted imaging is an integral part of an MR pelvic examination. However, fat suppression by conventional technique can be degraded by inhomogeneities of the magnetic field. The problem can be exacerbated when a typical large FOV is used for abdominal and pelvic imaging. Techniques that provide fat-suppressed T2-weighted imaging that is insensitive to field in...

متن کامل

Breast MRI Using a Balanced Steady-State Free Precession Imaging with a Two-Point Dixon Fat-Water Reconstruction Algorithm: Preliminary Experience and Comparison with 2D FSE

INTRODUCTION: Balanced steady-state free precession (b-SSFP) techniques yielding high SNR images in short scan times with T2-like image contrast have several appealing attributes for clinical breast MRI [1]. Clinical T2 imaging in the breast is routinely performed using a fat suppressed 2D Fast Spin Echo (FSE) pulse sequence with high in-plane spatial resolution. The 3-5 mm slice thickness obsc...

متن کامل

Improving fat-suppressed T2-weighted imaging of the head and neck with 2 fast spin-echo dixon techniques: initial experiences.

Two modified fast spin-echo (FSE) techniques (a 2-point and a single-scan triple-echo Dixon) were used for T2-weighted imaging of the head and neck in 7 patients along with conventional FSE with fat saturation. Both Dixon techniques provided consistent and more uniform fat suppression (FS) than conventional FSE. The 2-point Dixon technique was noted to be more susceptible to motion artifacts. T...

متن کامل

Single session whole body T2-weighted and T1-weighted MRI (both with and without fat suppression)

Introduction: An MRI study is commonly used for examining the local extent of a disease and often consists of acquiring images of the same region with different image contrasts. Using a moving tabletop and without re-positioning the patient, MRI has also been shown to be a feasible tool for whole body screening or staging of a disease [1-3]. In this regard, whole body MRI is potentially more ad...

متن کامل

Fast decomposition of water and lipid using a GRASE technique with the IDEAL algorithm.

Three-point Dixon techniques achieve good lipid-water separation by estimating the phase due to field inhomogeneities. Recently it was demonstrated that the combination of an iterative algorithm (iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL)) with a fast spin-echo (FSE) three-point Dixon method yielded robust lipid-water decomposition. As an a...