Three Dimensional Cone-beam Reconstruction of Micro Computed Tomography in the Breast Specimen
نویسندگان
چکیده
Traditionally, the specimen obtained from a breast biopsy can only be examined by a microscope. Although the resolution of microscope is high, it can only examine one thin section at a time. Hence, the microcalcifications next to the observed section may be missed. To solve for this problem, we acquire the specimen by a 3D micro computed tomography (microCT) with electron bombarded charged coupled device (EBCCD). The objective of this study was to implement and evaluate the 3D cone-beam reconstruction algorithms for the breast specimen using microCT. We have reconstructed the projections of specimen by parallel-beam, fan-beam, and cone-beam algorithms. For the cone-beam algorithm, we used the tent Feldkamp-Davis-Kress method (T-FDK) in this research. To evaluate the performance, we computed the coefficient of variation (CV) and contrast in the reconstructed images obtained from a cubic phantom, and analyzed the result by a t-test. From the results, we found that significant advantage of T-FDK over others. For the breast specimen, the microcalcifications can be easily identified in the images reconstructed using the T-FDK algorithm, but not in those reconstructed from the filtered backprojection (FBP). We then displayed these reconstructed images in 3D, and applied a 3D computer-aided diagnosis tool for classifying breast cancer. However, there are still some artifacts caused by these analytical reconstruction methods. For the future work, we plan to apply statistical iterative reconstruction methods in the microCT reconstruction, and expect the statistical reconstruction methods can reduce these artifacts.
منابع مشابه
Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality
Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...
متن کاملMethods to evaluate the performance of kilovoltage cone-beam computed tomography in the three-dimensional reconstruction space
Background: Cone-beam computed tomography (CBCT) scanners for image-guided radiotherapy are in clinical use today, but there has been no consensus on uniform acceptance to verify the CBCT image quality yet. The present work proposed new methods to fully evaluate the performance of CBCT in its three-dimensional (3D) reconstruction space. Materials and Methods: Compared to the traditional methods...
متن کاملکاربرد تکنیک تصویربرداری Cone Beam Computed Tomography در تشخیص ودرمان سنترال ژانت سل گرانولوما تومور ؛ گزارش یک مورد
Introduction: Central giant cell granuloma (CGCG) is a relatively rare and non neoplastic tumor with unclear exact etiology that is reported in children. Cone beam computed tomography (CBCT) technique for precise diagnosis and treatment of the jaw lesions is recommended in the recent years. The object of this case-report study is to use CBCT in the diagnosis and treatment of CGCG. Case Repor...
متن کاملThree Dimensional Study of Upper Airway in Different Antero-posterior Jaw Relationships through Cone Beam Computed Tomography
Introduction: This study aims at examining the difference of pharyngeal airways in patients with different occlusion postures, hoping to improve diagnostic methods and provide a stable treatment plan for orthodontic patients. Materials and Methods: The data were ga-thered through CBCT radiographies of patients from a specialized center for radiology. In each occlusion group according to the p...
متن کاملCorrelation Between Tissue Densities in Computed Tomography and Three Different Cone-Beam Computed Tomography Units (In Vitro)
Background and Aim: Bone density is of great assistance in the selection of the proper implant site. The present study aimed to assess the correlation between tissue densities in computed tomography (CT) and three different cone-beam computed tomography (CBCT) units. Materials and Methods: In this descriptive study, a radiographic phantom consisting of a transparent polymethyl methacrylate (PM...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -