Fully Automatic and Real-Time Catheter Segmentation in X-Ray Fluoroscopy

نویسندگان

  • Pierre Ambrosini
  • Daniel Ruijters
  • Wiro J. Niessen
  • Adriaan Moelker
  • Theo van Walsum
چکیده

Augmenting X-ray imaging with 3D roadmap to improve guidance is a common strategy. Such approaches benefit from automated analysis of the X-ray images, such as the automatic detection and tracking of instruments. In this paper, we propose a real-time method to segment the catheter and guidewire in 2D X-ray fluoroscopic sequences. The method is based on deep convolutional neural networks. The network takes as input the current image and the three previous ones, and segments the catheter and guidewire in the current image. Subsequently, a centerline model of the catheter is constructed from the segmented image. A small set of annotated data combined with data augmentation is used to train the network. We trained the method on images from 182 X-ray sequences from 23 different interventions. On a testing set with images of 55 X-ray sequences from 5 other interventions, a median centerline distance error of 0.2 mm and a median tip distance error of 0.9 mm was obtained. The segmentation of the instruments in 2D X-ray sequences is performed in a real-time fully-automatic manner.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Robust and Fast Contrast Inflow Detection for 2D X-ray Fluoroscopy

2D X-ray fluoroscopy is widely used in computer assisted and image guided interventions because of the real time visual guidance it can provide to the physicians. During cardiac interventions, acquisitions of angiography are often used to assist the physician in visualizing the blood vessel structures, guide wires, or catheters, localizing bifurcations, estimating severity of a lesion, or obser...

متن کامل

CathNets: Detection and Single-View Depth Prediction of Catheter Electrodes

Electrophysiology procedures are commonly carried out under guidance of C-arm fluoroscopy, but precise localization of the surgical instruments within the patients anatomy is done using expensive electro-anatomic mapping systems • Potential Alternative: Optical catheter detection, tracking & 3D reconstruction in fluoroscopic X-ray images • State of the Art: i) Gaussian blob detectors[3,4] for d...

متن کامل

Evaluation of the Quality Control Program for Diagnostic Radiography and Fluoroscopy Devices in Syria during 2005-2013

Introduction: Extensive use of diagnostic radiology is the largest contributor to total population radiation doses. Thus, appropriate equipment and safe practice are necessary for good-quality images with optimal doses. This study aimed to perform quality control (QC) audit for radiography and fluoroscopy devices owned by private sector in Syria (2005-2013) to verify compliance of performance o...

متن کامل

Cardiovascular Devices and Systems

Real-time imaging is required to guideminimally invasive catheter-based cardiac interventions. While transesophageal echocardiography allows for high-quality visualization of cardiac anatomy, X-ray fluoroscopy provides excellent visualization of devices. We have developed a novel image fusion system that allows real-time integration of 3-D echocardiography and the X-ray fluoroscopy. The system ...

متن کامل

Flexible robotics with electromagnetic tracking improves safety and efficiency during in vitro endovascular navigation.

OBJECTIVE One limitation of the use of robotic catheters is the lack of real-time three-dimensional (3D) localization and position updating: they are still navigated based on two-dimensional (2D) X-ray fluoroscopic projection images. Our goal was to evaluate whether incorporating an electromagnetic (EM) sensor on a robotic catheter tip could improve endovascular navigation. METHODS Six users ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017