A Multi-Site Analysis of Random Error in Tower-Based Measurements of Carbon and Energy Fluxes

نویسندگان

  • Andrew D. Richardson
  • David Y. Hollinger
  • George G. Burba
  • Kenneth J. Davis
  • Lawrence B. Flanagan
  • Gabriel G. Katul
  • J. William Munger
  • Daniel M. Ricciuto
  • Paul C. Stoy
  • Andrew E. Suyker
  • Shashi B. Verma
  • Steven C. Wofsy
چکیده

Measured surface-atmosphere fluxes of energy (sensible heat,H, and latent heat, LE) and CO2 (FCO2) represent the ‘‘true’’ flux plus or minus potential random and systematic measurement errors. Here, we use data from seven sites in the AmeriFlux network, including five forested sites (two of which include ‘‘tall tower’’ instrumentation), one grassland site, and one agricultural site, to conduct a cross-site analysis of random flux error. Quantification of this uncertainty is a prerequisite to model-data synthesis (data assimilation) and for defining confidence intervals on annual sums of net ecosystem exchange or making statistically valid comparisons between measurements and model predictions. We differenced paired observations (separated by exactly 24 h, under similar environmental conditions) to infer the characteristics of the random error in measured fluxes. Random flux error more closely follows a double-exponential (Laplace), rather than a normal (Gaussian), distribution, and increase as a linear function of the magnitude of the flux for all three scalar fluxes. Across sites, variation in the random error follows consistent and robust patterns in relation to environmental variables. For example, seasonal differences in the random error forH are small, in contrast to both LE and FCO2, for which the random errors are roughly three-fold larger at the peak of the growing season compared to the dormant season. Random errors also generally scale with Rn (H and LE) and PPFD (FCO2). For FCO2 (but not H or LE), the random error decreases with increasing wind speed. Data from two sites suggest that FCO2 random error may be slightly smaller when a closed-path, rather than open-path, gas analyzer is used. # 2006 Elsevier B.V. All rights reserved.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Energy and Second Law of Thermodynamics Analysis of Shower Cooling Tower with Variation in Inlet Air Temperature

A shower cooling tower (SCT) operates without fill because of salt decomposition on the fill that leads to deterioration of conventional cooling tower performance. This study presents a two-dimensional mathematical model for energy and exergy analysis of multi-diameter droplets and air interaction along with the height of the forced draft SCT, to predict the exit condition of water droplet for ...

متن کامل

Uncertainty in eddy covariance measurements and its application to physiological models.

Flux data are noisy, and this uncertainty is largely due to random measurement error. Knowledge of uncertainty is essential for the statistical evaluation of modeled and measured fluxes, for comparison of parameters derived by fitting models to measured fluxes and in formal data-assimilation efforts. We used the difference between simultaneous measurements from two towers located less than 1 km...

متن کامل

Uncertainty analysis of eddy covariance CO2 flux measurements for different EC tower distances using an extended two-tower approach

The use of eddy covariance (EC) CO2 flux measurements in data assimilation and other applications requires an estimate of the random uncertainty. In previous studies, the (classical) two-tower approach has yielded robust uncertainty estimates, but care must be taken to meet the often competing requirements of statistical independence (nonoverlapping footprints) and ecosystem homogeneity when ch...

متن کامل

Soil moisture controls on canopy-scale water and carbon fluxes in an African savanna

[1] Tower-based measurements of mass and energy exchanges at the end of the growing season in central Botswana were used to evaluate functional relationships commonly applied to predict water and carbon fluxes between savanna landscapes and the atmosphere. Following a large rainfall event, daily evapotranspiration (ETdaily) exhibited an exponential decay consistent with a derived analytical exp...

متن کامل

How energy and water availability constrain vegetation water-use along the North Australian Tropical Transect

Energy and water availability were identified as the first order controls of evapotranspiration(ET) in ecohyrodrology. With a ~1,000 km precipitation gradient and distinct wet-dry climate,the North Australian Tropical Transect (NATT) was well suited for evaluating how energy andwater availabilities constrain water use by vegetation, but has not been done yet. In this study,we addressed this que...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006