Effect of measurement conditions on measured levels of peak exhaled nitric oxide.
نویسندگان
چکیده
BACKGROUND It is possible to measure nitric oxide (NO) levels in exhaled air. The absolute concentrations of exhaled NO obtained by separate workers in similar patient groups and normal subjects with apparently similar techniques have been very different. A study was undertaken to determine whether changes in measurement conditions alter the concentration of exhaled NO. METHOD NO concentrations measured by a chemiluminescence analyser (Dasibi Environmental Corporation) and carbon dioxide (CO2) measured by a Morgan capnograph were analysed in single exhalations from total lung capacity in healthy volunteers (mean age 35.9 years). Ten subjects performed five exhalations at four different expiratory flow rates, at four different expiratory mouth pressures, and before and after drinking hot (n = 5) or cold (n = 5) water. Three subjects performed five exhalations on a day of high background NO (mean NO level 134 ppb) before and after a set of five exhalations made while both the subject and analysers were sampling from a low NO/NO-free reservoir system. RESULTS The mean peak concentration of NO decreased by 35 ppb (95% CI 25.7 to 43.4) from a mean (SE) of 79.0 (15.5) ppb at an expiratory flow rate of 250 ml/min to 54.1 (10.7) ppb at 1100 ml/min. The mean peak concentration of NO did not change significantly with change in mouth pressure. The mean (SE) peak NO concentration decreased from 94.4 (20.8) ppb to 70.8 (16.5) ppb (p = 0.002, 95% CI 12.9 to 33.1) with water consumption. The mean NO concentration with machine and subject sampling from the low NO reservoir was 123.1 (19.4) ppb, an increase from results obtained before (81.9 (10.2) ppb, p = 0.001, 95% CI -19.9 to -62.7) and after (94.2 (18.3) ppb, p = 0.017, 95% CI 6.0 to 51.8) sampling with high ambient NO. CONCLUSIONS The measurement of exhaled NO must be performed in a carefully standardised manner to enable different teams of investigators to compare results.
منابع مشابه
Is nitric oxide in exhaled air produced at airway or alveolar level?
The aim of this study was to determine whether the nitric oxide (NO) measured in exhaled air is produced at airway or alveolar level. Exhaled NO was measured using a chemiluminescence analyser, and carbon dioxide (CO2 concentration using a Morgan capnograph in single exhalations in 12 healthy subjects (mean age 32 yrs; 6 males and 6 females). For each subject, five exhalations were made directl...
متن کاملThe Importance of Exhaled Nitric Oxide Concentration in Asthmatic Patients and Factors that Impact its Measurement
Measurement of exhaled nitric oxide (FeNO) concentration is a simple, reproducible, and noninvasive means of identifying the extent of airway inflammation and disease control in asthma. Accuracy of FeNO measurements depends on certain host-related factors such as atopy, sex, diet, and environmental factors such as ambient conditions and measurement technique. In this study, we aimed to assess t...
متن کاملIncreased nitric oxide in exhaled air of normal human subjects with upper respiratory tract infections.
Viral infection may induce the expression of nitric oxide (NO) synthase, resulting in increased NO formation that has an antiviral effect. NO may be produced by various cells of the upper and lower respiratory tract, and may be detected in the exhaled air. We have studied the levels of exhaled NO in 18 normal subjects during symptomatic upper respiratory tract infections and during recovery 3 w...
متن کاملRelationship between exhaled air temperature and exhaled nitric oxide in childhood asthma.
Airway inflammation is a characteristic of asthma. Exhaled nitric oxide (eNO) has been demonstrated to be related to actual levels of airway inflammation in asthmatic patients. The purpose of this study was to investigate whether the temperature of exhaled air is related to eNO levels. Temperature of exhaled air and eNO were measured in 52 asthmatic children with a cross-sectional design. A sig...
متن کاملInfluence of atmospheric nitric oxide concentration on the measurement of nitric oxide in exhaled air.
BACKGROUND Measurement of nitric oxide (NO) in exhaled air shows promise as a non-invasive method of detecting lung inflammation. However, variable concentrations of NO are measured in environmental air. The aim of this study was to verify a possible relationship between exhaled NO and atmospheric NO values during high atmospheric NO days. METHOD Exhaled air from 78 healthy non-smokers of mea...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Thorax
دوره 52 8 شماره
صفحات -
تاریخ انتشار 1997