An experimental technique for measuring the temperature rise during impact testing

نویسندگان

  • S. Craig
  • D. Gaskell
  • P. Rockett
  • C. Ruiz
چکیده

A fast response radiometer and its associated instrumentation for the measurement of the temperature reached during impact is described in this paper. It is based on a thermoelectrically cooled HgCdTe detector. The sensitivity and time response have been determined by means of static calibration tests, within the range +25 to 500 "C, and a dynamic calibration using an optical chopper at 1.35 kHz. Some results of compression tests are provided.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rate of Pressure Rise in SI Engine Cylinder and its Relation to Knock (RESEARCH NOTE)

Tremendous efforts have been devoted to study the complex phenomenon "knock in spark ignition engines. There is an increasing interest in providing some tools to study knock in simulated data. In the previous studies, engine cylinder pressure oscillation has been used to investigate knock. Unless those methods involved highly complex non-detailed chemical relations, the previous studies were de...

متن کامل

مقایسه برخی خصوصیات رزین‌های رستوریشن موقت Trim، Tempron، Acropars TRII وDuralay (Aria Dent)

Background and Aim: Use of provisional restorations is one of the important phases in the treatment of patients who need fixed prosthesis. Some physical properties are required for these materials. The purpose of this study was the comparison of some physical properties of 4 kinds of resins: Trim, Tempron, Duralay (Aria Dent) and Acropars TRII. Materials and Methods: In this experimental study,...

متن کامل

Testing of Environment Friendly Refrigerant R290 for Water Cooler Application (RESEARCH NOTE)

This paper presents environment friendly refrigerant R290 as a solution to the environmental concerns like depletion of ozone layer and rise in global warming because of wide use of synthetic refrigerants R22 and R134a. The water cooler is the widely used refrigeration application in warm climatic countries. Refrigerant R22 and R134a are predominantly used refrigerants in water cooler refrigera...

متن کامل

Thickness Measuring of Thin Metal by Non Destructive with Fuzzy Logic Control System

Non-Destructive Testing & Evaluation methods are developed to inspect and investigate materials and structures. Ultrasonic Testing is an NDT method can be used for measuring the thickness of objects, as one of its significant applications. The objective of this paper is designing and applying an intelligent UT fuzzy control system for evaluating the thickness of thin metal objects in a range of...

متن کامل

Thickness Measuring of Thin Metal by Non Destructive with Fuzzy Logic Control System

Non-Destructive Testing & Evaluation methods are developed to inspect and investigate materials and structures. Ultrasonic Testing is an NDT method can be used for measuring the thickness of objects, as one of its significant applications. The objective of this paper is designing and applying an intelligent UT fuzzy control system for evaluating the thickness of thin metal objects in a range of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016