Voltage changes in the lithium dilution cardiac output sensor after exposure to blood from horses given xylazine.

نویسندگان

  • T D Ambrisko
  • Y Moens
چکیده

BACKGROUND In a previous in vitro study using saline medium, the authors showed that certain drugs changed the voltages of lithium dilution cardiac output (LiDCO) sensors and also influenced their accuracy in measuring lithium concentrations. These two parameters correlated and so we examined whether such drug-sensor interaction exists when LiDCO sensor was exposed to xylazine in blood. METHODS Five healthy adult warm-blood horses were injected with 0.5 mg kg(-1) xylazine i.v. Physiological saline solution and venous blood were consecutively sampled through the same LiDCO sensor at 60, 45, 30, 15, and 0 min before and then 5, 15, 30, 45, and 60 min after xylazine injection. Sensor voltages were recorded and the differences between saline- and blood-exposed sensor voltages were compared at each time point. RESULTS Saline-exposed sensor voltages continuously increased in a non-linear pattern during the experiment. Blood-exposed sensor voltages also increased in a similar pattern, but it was interrupted by an abrupt increase in voltage after xylazine injection. The differences between saline- and blood-exposed sensor voltages were 7 (6.1-8) mV [median (range)] before xylazine but decreased significantly at 5 and 15 min after xylazine treatment. The highest drug-induced voltage change was 3.4 (1.6-7) mV. CONCLUSIONS This study showed that exposure of a LiDCO sensor to blood after a single clinically relevant dose of xylazine in horses changed the voltages of the sensors for 15 min. Comparison of saline- and blood-exposed sensor voltages could become a tool to detect drug-sensor interactions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

TRANSLATIONAL RESEARCH Influence of drugs on the response characteristics of the LiDCO sensor: an in vitro study

Editor’s key points † Previous work in animals suggested that certain anaesthetic drugs affect the accuracy of the LiDCO cardiac output monitor. † In this laboratory study, a2 agonists, ketamine, lidocaine, and rocuronium all produced a bias of .10% in the LiDCO voltage sensor. † These might potentially cause inaccuracies when using the LiDCO device. † Further work is needed to confirm these fi...

متن کامل

A new method of measuring cardiac output in man using lithium dilution.

We describe a new indicator dilution method of measuring cardiac output in man. A bolus injection of lithium chloride 0.6 mmol was given via a central venous catheter and arterial plasma [Li+] recorded using a specially developed sensor incorporating an Li(+)-selective electrode. Cardiac output was derived from the lithium dilution curve, with a correction for packed cell volume. Lithium diluti...

متن کامل

Evaluation of cardiac troponin I, atrial natriuretic peptide and some oxidative/antioxidative biomarkers in the serum and hemolysate of trained Arabian horses after exercise

Background: Limited information existed on performance tests in Iranian Arab horses. Aims: The objective of this study is to investigate time related changes of cardiac troponin I (cTnI), atrial natriuretic peptide (ANP) and oxidative/antioxidant biomarkers in the serum of Arabian horses before and after regular training. Methods: Blood samples were collected from jugular vein of 25 Arabian hor...

متن کامل

Blood glucose, acid-base and electrolyte changes during loading doses of alpha₂-adrenergic agonists followed by constant rate infusions in horses.

The aim of the present study was to investigate changes in blood glucose concentration ([Glu]B), acid-base status and electrolyte concentrations during constant rate infusions (CRI) of two alpha2-adrenergic agonists in seven horses treated in a blinded, randomised, crossover design with xylazine or romifidine. An intravenous (IV) bolus of xylazine (1mg/kg) or romifidine (80 μg/kg) was administe...

متن کامل

PulseCO: a less-invasive method to monitor cardiac output from arterial pressure after cardiac surgery.

BACKGROUND Cardiac output is often monitored after cardiac operations with a pulmonary artery catheter. A new method has been introduced that measures cardiac output by lithium dilution (LiDCO) and uses these data to calibrate a system (PulseCO) that calculates cardiac output continuously from the energy of the arterial pressure waveform. It is unknown whether PulseCO measurements are valid ear...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 112 2  شماره 

صفحات  -

تاریخ انتشار 2014