On-line measurement of electroosmosis in capillary electrophoresis using a conductivity cell

نویسندگان

  • Bart J. Wanders
  • Frans M. Everaerts
چکیده

• A submitted manuscript is the author's version of the article upon submission and before peer-review. There can be important differences between the submitted version and the official published version of record. People interested in the research are advised to contact the author for the final version of the publication, or visit the DOI to the publisher's website. • The final author version and the galley proof are versions of the publication after peer review. • The final published version features the final layout of the paper including the volume, issue and page numbers.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

On-column conductivity detection in capillary-chip electrophoresis.

On-column conductivity detection in capillary-chip electrophoresis was achieved by actively coupling the high electric field with two sensing electrodes connected to the main capillary channel through two side detection channels. The principle of this concept was demonstrated by using a glass chip with a separation channel incorporating two double-Ts. One double-T was used for sample introducti...

متن کامل

Electroosmotic flow control of fluids on a capillary electrophoresis microdevice using an applied external voltage

Independent control of electroosmosis is important for separation science techniques such as capillary zone electrophoresis and for the movement of fluids on microdevices. A capillary electrophoresis microdevice is demonstrated which provides more efficient control of electroosmosis with an applied external voltage field. The device is fabricated in a glass substrate where a 5.0 cm separation c...

متن کامل

Introducing a New and Simple Protocol for Capillary Electrophoresis of Cell Free Fetal Double Stranded DNA

Isolation of cell free fetal DNA (cffDNA) from maternal serum usually leads to very low concentrations of DNA impeding further resolving through conventional methods of electrophoresis. Although several protocols have been described for capillary electrophoresis (CE) of double stranded DNA, they usually need using special polymers or coated capillaries which degrade over time. Herein, we propos...

متن کامل

Effect of Capillary Rinsing Protocol on the Reproducibility of Separation in Capillary Electrophoresis with Indirect UV Detection

Capillary electrophoresis (CE) with indirect UV detection is an interesting analytical method for the analysis of drugs and pharmaceuticals. Good and reproducible capillary quality is needed to develop robust methods and to facilitate method transfer in CE. It is widely accepted that preconditioning procedures are indispensable in capillary electrophoresis in order to achieve reproducibility of...

متن کامل

Extension of External Voltage Control of Electroosmosis to High-pH Buffers.

Control of electroosmosis by an applied external voltage field in capillary electrophoresis has been limited to buffer pH approximately 5 or below. This poor control at higher pH is caused by a high density of surface charge induced by chemical equilibrium overwhelming the influence of the external voltage-induced charges within the electric double layer. A tert-butyldiphenylchlorosilane treatm...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017