A non-MVC EMG normalization technique for the trunk musculature: Part 1. Method development.

نویسندگان

  • W S Marras
  • K G Davis
چکیده

Normalization of muscle activity has been commonly used to determine the amount of force exerted by a muscle. The most widely used reference point for normalization is the maximum voluntary contraction (MVC). However, MVCs are often subjective, and potentially limited by sensation of pain in injured individuals. The objective of the current study was to develop a normalization technique that predicts an electromyographic (EMG) reference point from sub-maximal exertions. Regression equations predicting maximum exerted trunk moments were developed from anthropometric measurements of 120 subjects. In addition, 20 subjects performed sub-maximal and maximal exertions to determine the necessary characteristic exertions needed for normalization purposes. For most of the trunk muscles, a highly linear relationship was found between EMG muscle activity and trunk moment exerted. This analysis determined that an EMG-moment reference point can be obtained via a set of sub-maximal exertions in combination with a predicted maximal exertion (expected maximum contraction or EMC) based upon anthropometric measurements. This normalization technique overcomes the limitations of the subjective nature for the MVC method providing a viable assessment method of individuals with a low back injury or those unwilling to exert an MVC as well as could be extended to other joints/muscles.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A non-MVC EMG normalization technique for the trunk musculature: Part 2. Validation and use to predict spinal loads.

Estimates of the amount of force exerted by a muscle using electromyography (EMG) rely partially upon the accuracy of the reference point used in the normalization technique. Accurate representations of muscle activities are essential for use in EMG-driven spinal loading models. The expected maximum contraction (EMC) normalization method was evaluated to explore whether it could be used to asse...

متن کامل

An EMG-assisted model calibration technique that does not require MVCs.

As personalized biologically-assisted models of the spine have evolved, the normalization of raw electromyographic (EMG) signals has become increasingly important. The traditional method of normalizing myoelectric signals, relative to measured maximum voluntary contractions (MVCs), is susceptible to error and is problematic for evaluating symptomatic low back pain (LBP) patients. Additionally, ...

متن کامل

Electromyographic (EMG) normalization method for cycle fatigue protocols.

PURPOSE To determine the most effective electromyographic (EMG) normalization method for cycling fatigue protocols. METHODS Ten healthy subjects performed two 5-s isometric knee extension maximal voluntary contractions (MVC) at a knee joint angle of 60 degrees, two fixed cycle pedal contraction at knee joint angles of 60 degrees (60 degrees A) and 108 degrees (108 degrees A), and a dynamic si...

متن کامل

Elastic resistance exercises for prevention of trunk deformities - a case study

Subjects and methods The present pilot study is a case report on a single proband. Surface EMG (Noraxon) was recorded on one healthy subject during 3 resistive exercises using TheraBand (blue color). EMG activity during the agistic-excentric-exercises was analyzed on m. obliquus abdominis int., m. rectus abdominis, m. latissimus dorsi, m.erector spinae TH-L on the right and left side. The EMG a...

متن کامل

Biomechanical analysis of functional electrical stimulation on trunk musculature during wheelchair propulsion.

BACKGROUND The objective of this study was to examine how surface electrical stimulation of trunk musculature influences the kinematic, kinetic, and metabolic characteristics, as well as shoulder muscle activity, during wheelchair propulsion. METHODS Eleven participants with spinal cord injury propelled their own wheelchairs on a dynamometer at a speed of 1.3 m/s for three 5-minute trials. Du...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology

دوره 11 1  شماره 

صفحات  -

تاریخ انتشار 2001