Difference between the default telecoil (t-coil) and programmed microphone frequency response in behind-the-ear (BTE) hearing aids.

نویسندگان

  • Daniel B Putterman
  • Michael Valente
چکیده

BACKGROUND A telecoil (t-coil) is essential for hearing aid users when listening on the telephone because using the hearing aid microphone when communicating on the telephone can cause feedback due to telephone handset proximity to the hearing aid microphone. Clinicians may overlook the role of the t-coil due to a primary concern of matching the microphone frequency response to a valid prescriptive target. Little has been published to support the idea that the t-coil frequency response should match the microphone frequency response to provide "seamless" and perhaps optimal performance on the telephone. If the clinical goal were to match both frequency responses, it would be useful to know the relative differences, if any, that currently exist between these two transducers. PURPOSE The primary purpose of this study was to determine if statistically significant differences were present between the mean output (in dB SPL) of the programmed microphone program and the hearing aid manufacturer's default t-coil program as a function of discrete test frequencies. In addition, pilot data are presented on the feasibility of measuring the microphone and t-coil frequency response with real-ear measures using a digital speech-weighted noise. RESEARCH DESIGN A repeated-measures design was utilized for a 2-cc coupler measurement condition. Independent variables were the transducer (microphone, t-coil) and 11 discrete test frequencies (15 discrete frequencies in the real-ear pilot condition). STUDY SAMPLE The study sample was comprised of behind-the-ear (BTE) hearing aids from one manufacturer. Fifty-two hearing aids were measured in a coupler condition, 39 of which were measured in the real-ear pilot condition. Hearing aids were previously programmed and verified using real-ear measures to the NAL-NL1 (National Acoustic Laboratories-Non-linear 1) prescriptive target by a licensed audiologist. DATA COLLECTION AND ANALYSIS Hearing aid output was measured with a Fonix 7000 hearing aid analyzer (Frye Electronics, Inc.) in a HA-2 2-cc coupler condition using a pure-tone sweep at an input level of 60 dB SPL with the hearing aid in the microphone program and 31.6 mA/M in the t-coil program. A digital speech weighted noise input signal presented at additional input levels was used in the real-ear pilot condition. A mixed-model repeated-measures analysis of variance (ANOVA) and the Tukey Honestly Significant Difference (HSD) post hoc test were utilized to determine if significant differences were present in performance across treatment levels. RESULTS There was no significant difference between mean overall t-coil and microphone output averaged across 11 discrete frequencies (F(1,102) = 0, p < 0.98). A mixed-model repeated-measures ANOVA revealed a significant transducer by frequency interaction (F(10,102) = 13.0, p < 0.0001). Significant differences were present at 200 and 400 Hz where the mean t-coil output was less than the mean microphone output, and at 4000, 5000, and 6300 Hz where the mean t-coil output was greater than the mean microphone output. CONCLUSIONS The mean t-coil output was significantly lower than the mean microphone output at 400 Hz, a frequency that lies within the typical telephone bandwidth of 300-3300 Hz. This difference may partially help to explain why some patients often complain the t-coil fails to provide sufficient loudness for telephone communication.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Difference between default telecoil and programmed microphone frequency response in behind-the-ear hearing aids

The notion that the default telecoil (t-coil) frequency response should match the programmed microphone frequency response to provide optimal telephone understanding for hearing aid patients has received little attention. This study addresses differences in the average frequency response of the two transducers in behind-the-ear (BTE) hearing aids. copyright by Daniel B. Putterman May 2011

متن کامل

Effect of microphone location in ITE versus BTE hearing aids.

Sound pressure measurements were made at the hearing aid microphones of 20 subjects with their in-the-ear (ITE) hearing aids and a behind-the-ear (BTE) hearing aid to determine the influence of microphone location on hearing aid input. A probe tube microphone was used to measure the difference in dB SPL between the ITE and BTE microphone locations. ITE microphone location resulted in a maximum ...

متن کامل

A Microphone Array for Hearing Aids

A directional acoustic receiving system is constructed in the form of a necklace including an array of two or more microphones mounted on a housing supported on the chest of a user by a conducting loop encircling the users neck. Signal processing electronics contained in the same housing receive and combine the microphone signals in such a manner as to provide an amplified output signal which e...

متن کامل

Speech recognition with in-the-ear and behind-the-ear dual-microphone hearing instruments.

The primary purpose of this study was to compare the overall listening benefit in diffuse noise provided by dual-microphone technology in an in-the-ear (ITE) hearing instrument to that provided by dual-microphone technology in a behind-the-ear (BTE) hearing instrument. Further, the study was designed to determine whether the use of the dual-microphone + the manufacturer's party response algorit...

متن کامل

Probe-microphone measurements with body-worn instruments: loudspeaker and reference microphone effects.

Probe-microphone measurements are typically made with behind-the-ear (BTE) and in-the-ear (ITE) hearing aids with the loudspeaker located at 0-degrees or 45-degrees azimuth at head level and the reference microphone positioned on the head near the hearing aid microphone. With body-worn instruments, these conditions may not accurately reflect in situ hearing aid performance. This study compared ...

متن کامل