Simultaneous z-shim method for reducing susceptibility artifacts with multiple transmitters.
نویسندگان
چکیده
The signal loss susceptibility artifact is a major limitation in gradient-echo MRI applications. Various methods, including z-shim techniques and multidimensional tailored radio frequency (RF) pulses, have been proposed to mitigate the through-plane signal loss artifact, which is dominant in axial slices above the sinus region. Unfortunately, z-shim techniques require multiple steps and multidimensional RF methods are complex, with long pulse lengths. Parallel transmission methods were recently shown to be promising for improving B1 inhomogeneity and reducing the specific absorption rate. In this work, a novel method using time-shifted slice-select RF pulses is presented for reducing the through-plane signal loss artifact in parallel transmission applications. A simultaneous z-shim is obtained by concurrently applying unique time-shifted pulses on each transmitter. The method is shown to reduce the signal loss susceptibility artifact in gradient-echo images using a four-channel parallel transmission system at 3T.
منابع مشابه
Reducing susceptibility artifacts in fMRI using volume-selective z-shim compensation.
Susceptibility-induced magnetic field gradients (SFGs) can result in severe signal loss in the orbitofrontal cortex (OFC) in gradient-echo-based functional MRI (fMRI) studies. Although conventional z-shim techniques can effectively recover the MRI signal in this region, the substantial penalty in imaging time hampers their use in routine fMRI studies. A modified z-shim technique with high imagi...
متن کامل3D z-shim method for reduction of susceptibility effects in BOLD fMRI.
Susceptibility-induced magnetic field gradients (SFGs) perpendicular to the slice plane often result in signal dropout in blood oxygenation level-dependent (BOLD) functional magnetic resonance imaging (fMRI) experiments. Two-dimensional (2D) z-shim methods reduce these effects by acquiring multiple images with different slice refocusing gradient areas. In this work a 3D z-shim method is introdu...
متن کاملImproved susceptibility weighted imaging method using multi-echo acquisition.
PURPOSE To introduce novel acquisition and postprocessing approaches for susceptibility weighted imaging (SWI) to remove background field inhomogeneity artifacts in both magnitude and phase data. METHODS The proposed method acquires three echoes in a three-dimensional gradient echo (GRE) sequence, with a field compensation gradient (z-shim gradient) applied to the third echo. The artifacts in...
متن کاملSimultaneous acquisition of gradient-echo and asymmetric spin-echo for single-shot z-shim: Z-SAGA.
This article describes the Z-SAGA pulse sequence, a technique for recovering susceptibility losses in EPI images for neuroimaging applications. The pulse sequence is based on an asymmetric spin echo EPI sequence and acquires a gradient echo image and an asymmetric spin echo image in a single shot. For one of the images, a z-shim gradient pulse is applied to compensate for susceptibility-related...
متن کاملArtifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality
Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Magnetic resonance in medicine
دوره 61 2 شماره
صفحات -
تاریخ انتشار 2009