Lead systems for internal ventricular fibrillation.
نویسندگان
چکیده
We examined the feasibility of using a standby automatic implantable defibrillator and established thresholds for internal defibrillation. The implantable defibrillator senses ventricular fibrillation and delivers an electrical impulse for defibrillation. Two lead systems for the device have been investigated. System I consists of two 12-cm2 silicone-covered titanium mesh patches attached to the atrial and diaphragmatic pericardial surfaces. System II has an identical diaphragmatic patch and a titanium spring catheter, with a 12-cm2 surface area of conductivity, placed transvenously in the right atrium. Both systems were implanted by thoracotomy in 12 dogs (mean weight 20 kg) and by a subxiphoid approach in 10 pigs (mean weight 20 kg). The defibrillation threshold (lowest energy required for 80% success) was determined periodically for 54 weeks in the dogs (615 trials) and at 6 weeks for the pigs (100 trials). In dogs, the mean defibrillation threshold with system I leads at 4 weeks was 10.5 J and did not change significantly over a 54-week period (p greater than 0.05). Similar results were obtained in the pig at 4 weeks. The defibrillation thresholds for both lead systems in dogs and pigs using a transpleural thoracotomy or a subxiphoid approach are satisfactory for an implantable defibrillator that produces 20-35 J.
منابع مشابه
Ellagic acid improved arrhythmias induced by CaCL2 in the rat stress model
Objective: In ventricular arrhythmias, due to their free radical scavenging action, antioxidant agents are usually used in the treatment of cardiovascular disease. Since stress is considered as risk factor for increased mortality by causing malignant arrhythmias, the study was designed to evaluate the cardioprotective effects of ellagic acid (EA) on CaCl2-induced arrhythmias in rat stress model...
متن کاملInternal cardioversion of atrial fibrillation in sheep.
BACKGROUND The cardioversion efficacy of multiple defibrillation waveforms and electrode systems was compared in a sheep model of atrial fibrillation. METHODS AND RESULTS Sustained atrial fibrillation could be induced with rapid atrial pacing in 23 (55%) of the animals. This study was performed in four parts. Six sheep with sustained atrial fibrillation were used for data analysis for each pa...
متن کاملIntraoperative Defibrillation Testing of Subcutaneous Implantable Cardioverter‐Defibrillator Systems—A Simple Issue?
BACKGROUND The results of the recently published randomized SIMPLE trial question the role of routine intraoperative defibrillation testing. However, testing is still recommended during implantation of the entirely subcutaneous implantable cardioverter-defibrillator (S-ICD) system. To address the question of whether defibrillation testing in S-ICD systems is still necessary, we analyzed the dat...
متن کاملSUDDEN VENTRICULAR FIBRILLATION DURING CATHE TERIZATION DUE TO LIDOCAINE INFILTRATION FOR LOCAL ANESTHESIA IN A 53 YEAR OLD WOMAN
Mrs. Heidari, 53 developed ventricular fibrillation and cardiopulmonary arrest after receiving 15 mL lidocaine 2% for local anesthesia at the Dr. Shariati Hospital Cathlab. There was no identified risk factor for her arrest preoperatively. She had a history of exertional chest pain for about 5 years and an electrocardiogram showed only inverted T-waves at the time of angiography. The case i...
متن کاملInternal Cardioversion of Atrial Fibrillation in Sheep Randolph
Background. The cardioversion efficacy of multiple defibrillation waveforms and electrode systems was compared in a sheep model of atrial fibrillation. Methods and Results. Sustained atrial fibrillation couldbe induced with rapid atrial pacing in 23 (55%) of the animals. This study was performed in four parts. Six sheep with sustained atrial fibrillation were used for data analysis for each par...