Velocity Measurement in Carotid Artery: Quantitative Comparison of Time-Resolved 3D Phase-Contrast MRI and Image-based Computational Fluid Dynamics

نویسندگان

  • Ali Sarrami-Foroushani
  • Mohsen Nasr Esfahany
  • Abbas Nasiraei Moghaddam
  • Hamidreza Saligheh Rad
  • Kavous Firouznia
  • Madjid Shakiba
  • Hossein Ghanaati
  • Iain David Wilkinson
  • Alejandro Federico Frangi
چکیده

BACKGROUND Understanding hemodynamic environment in vessels is important for realizing the mechanisms leading to vascular pathologies. OBJECTIVES Three-dimensional velocity vector field in carotid bifurcation is visualized using TR 3D phase-contrast magnetic resonance imaging (TR 3D PC MRI) and computational fluid dynamics (CFD). This study aimed to present a qualitative and quantitative comparison of the velocity vector field obtained by each technique. SUBJECTS AND METHODS MR imaging was performed on a 30-year old male normal subject. TR 3D PC MRI was performed on a 3 T scanner to measure velocity in carotid bifurcation. 3D anatomical model for CFD was created using images obtained from time-of-flight MR angiography. Velocity vector field in carotid bifurcation was predicted using CFD and PC MRI techniques. A statistical analysis was performed to assess the agreement between the two methods. RESULTS Although the main flow patterns were the same for the both techniques, CFD showed a greater resolution in mapping the secondary and circulating flows. Overall root mean square (RMS) errors for all the corresponding data points in PC MRI and CFD were 14.27% in peak systole and 12.91% in end diastole relative to maximum velocity measured at each cardiac phase. Bland-Altman plots showed a very good agreement between the two techniques. However, this study was not aimed to validate any of methods, instead, the consistency was assessed to accentuate the similarities and differences between Time-resolved PC MRI and CFD. CONCLUSION Both techniques provided quantitatively consistent results of in vivo velocity vector fields in right internal carotid artery (RCA). PC MRI represented a good estimation of main flow patterns inside the vasculature, which seems to be acceptable for clinical use. However, limitations of each technique should be considered while interpreting results.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reconstruction of carotid bifurcation hemodynamics and wall thickness using computational fluid dynamics and MRI.

A thorough understanding of the relationship between local hemodynamics and plaque progression has been hindered by an inability to prospectively monitor these factors in vivo in humans. In this study a novel approach for noninvasively reconstructing artery wall thickness and local hemodynamics at the human carotid bifurcation is presented. Three-dimensional (3D) models of the lumen and wall bo...

متن کامل

New Methods for Computational Fluid Dynamics Modeling of Carotid Artery from Magnetic Resonance Angiography

Computational fluid dynamics (CFD) models of the carotid artery are constructed from contrast-enhanced magnetic resonance angiography (MRA) using a deformable model and a surface-merging algorithm. Physiologic flow conditions are obtained from cine phase-contrast MRA at two slice locations below and above the carotid bifurcation. The methodology was tested on image data from a rigid flow-throug...

متن کامل

4D phase contrast MRI in intracranial aneurysms: a comparison with patient-specific computational fluid dynamics with temporal and spatial velocity boundary conditions as measured with 3D phase contrast MRI

Background It is believed that hemodynamic factors contribute significantly to aneurysm formation, growth and rupture. Studies attempting to predict risk factors are mostly based on computational fluid dynamics (CFD). A disadvantage of CFD is that among other assumptions, often non-patient-specific inflow conditions are prescribed. 4D phase contrast MRI (4D PCMRI) for the assessment of hemodyna...

متن کامل

Computational fluid dynamics simulations of blood flow regularized by 3D phase contrast MRI.

BACKGROUND Phase contrast magnetic resonance imaging (PC-MRI) is used clinically for quantitative assessment of cardiovascular flow and function, as it is capable of providing directly-measured 3D velocity maps. Alternatively, vascular flow can be estimated from model-based computation fluid dynamics (CFD) calculations. CFD provides arbitrarily high resolution, but its accuracy hinges on model ...

متن کامل

Particle Trace Visualization of Cardiac Flow Patterns using 3D Phase Contrast MRI: An in vitro Comparison with Streamlines Created using Dye

Introduction Intracardiac flow patterns can be visualized by particle traces obtained from three-dimensional phase contrast MRI. Good results have been shown for stationary [1] and time-resolved data [2]. New off-line retrospective gated 3D phase contrast techniques, providing high resolution time-resolved 3D velocity data, have improved the accuracy of the calculated particle traces [3]. While...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2015