Fitting Characteristics of N95 Filtering-Facepiece Respirators Used Widely in China

نویسندگان

  • Yanyan Yu
  • Luman Jiang
  • Ziqing Zhuang
  • Yuewei Liu
  • Xinyan Wang
  • Juyuan Liu
  • Mingna Yang
  • Weihong Chen
چکیده

BACKGROUND Millions of people rely on N95 filtering facepiece respirators to reduce the risk of airborne particles and prevent them from respiratory infections. However, there are no respirator fit testing and training regulations in China. Meanwhile, no study has been conducted to investigate the fit of various respirators. The objective of this study was to investigate whether people obtained adequate fit when wearing N95 filtering facepiece respirators (FFRs) used widely in China. METHODS Fifty adult participants selected using the Chinese respirator fit test panel donned 10 common models of N95 FFRs. Fit factors (FF) and inward leakage were measured using the TSI PortaCount Plus. Each subject was tested with three replications for each model. A subject was considered to pass the fit test when at least two of the three FFs were greater than 100. Two models were conducted fit tests before and after training to assess the role of training. RESULTS The geometric mean FFs for each model and trained subjects ranged from <10 to 74.0. The fifth percentile FFs for only two individual respirator models were greater than 10 which is the expected level of performance for FFRs. The passing rates for these two models of FFRs were 44.7% and 20.0%. The passing rates were less than 10.0% for the other eight models. There were 27 (54%) participants who passed none of the 10 FFRs. The geometric mean FFs for both models when the subjects received training (49.7 and 74.0) were significantly larger than those when the same group of subjects did not receive any training (29.0 and 30.9) (P<0.05). CONCLUSIONS FFRs used widely in China should be improved according to Chinese facial dimensions. Respirator users could benefit from respirator training and fit testing before using respirators.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of a quantitative fit testing method for N95 filtering facepiece respirators.

A method for performing quantitative fit tests (QNFT) with N95 filtering facepiece respirators was developed by earlier investigators. The method employs a simple clamping device to allow the penetration of submicron aerosols through N95 filter media to be measured. The measured value is subtracted from total penetration, with the assumption that the remaining penetration represents faceseal le...

متن کامل

Evaluation of Multiple (3-Cycle) Decontamination Processing for Filtering Facepiece Respirators

Disposable N95 filtering facepiece respirators (FFRs) certified by the National Institute for Occupational Safety and Health (NIOSH) are widely used by healthcare workers to reduce exposures to infectious biological aerosols. There is currently major concern among public health officials about a possible shortage of N95 FFRs during an influenza pandemic. Decontamination and reuse of FFRs is a p...

متن کامل

Respiratory protection provided by N95 filtering facepiece respirators against airborne dust and microorganisms in agricultural farms.

A new system was used to determine the workplace protection factors (WPF) for dust and bioaerosols in agricultural environments. The field study was performed with a subject wearing an N95 filtering facepiece respirator while performing animal feeding, grain harvesting and unloading, and routine investigation of facilities. As expected, the geometric means (GM) of the WPFs increased with increa...

متن کامل

Effect of surgical masks worn concurrently over N95 filtering facepiece respirators: extended service life versus increased user burden.

Growing concern over the availability of Respiratory protective devices (eg, filtering facepiece Respirators), in the face of the probable extreme demand brought on by a pandemic influenza, has prompted the suggestion that useful life of N95 filtering facepiece Respirator can be extended by the concurrent use of a surgical mask as an outer protective barrier over the Respirator. Personal protec...

متن کامل

Comparison of Simulated Workplace Protection Factors Offered by N95 and P100 Filtering Facepiece and Elastomeric Half-Mask Respirators against Particles of 10 to 400 nm

This study compared the simulated workplace protection factors (SWPFs) between NIOSH-approved N95 respirators and P100 respirators, including two models of filtering facepiece respirator (FFR) and two models of elastomeric half-mask respirator (EHR), against sodium chloride particles (NaCl) in a range of 10 to 400 nm. Twenty-five human test subjects performed modified OSHA fit test exercises in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014