Automatic Positioning of a Surgical Microscope

نویسندگان

  • Markus Finke
  • Tobias Meyer
  • Maik Stille
  • Achim Schweikard
چکیده

A procedure for interactive navigation of a fully motorized surgical microscope is presented. This procedure uses preoperative MRTor CT-images to generate a 3D-model of the patient which then acts as the basis for navigation during surgery. The relation between tracking system, microscope and 3D-model is established using a simple calibration method based on the Horn [Ho87] algorithm. It enables positioning the microscope by defining target points either directly on the patient using an optical marker or on his 3D-model. After reaching the target position the microscope focuses automatically by calculating the focus score of the current field of view as function of the working distance. Thus, not only the surgeon will be discharged from positioning the microscope but he can also continue his work almost immediately. Manual interaction becomes unnecessary.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Short Introduction

Microsurgery not only means working with the help of a surgical microscope. One of themajor advantages lies in the possibility to perform operations through small skin incisions (“keyhole surgery”). This needs meticulous preoperative planning, exact positioning of the patient, and reliable localization of the surgical target area in projection to the entry level on the skin surface. All these f...

متن کامل

Microscope-integrated optical coherence tomography for image-aided positioning of glaucoma surgery.

Most glaucoma surgeries involve creating new aqueous outflow pathways with the use of a small surgical instrument. This article reported a microscope-integrated, real-time, high-speed, swept-source optical coherence tomography system (SS-OCT) with a 1310-nm light source for glaucoma surgery. A special mechanism was designed to produce an adjustable system suitable for use in surgery. A two-grap...

متن کامل

Image quality enhancement in digital panoramic radiograph

One of the most common positioning errors in panoramic radiography is palatoglossal air space above the apices of the root of maxillary teeth. It causes a radiolucency obscuring the apices of maxillary teeth. In the case of this positioning error, the imaging should be repeated. This causes the patient be exposed to radiation again. To avoid the repetition of exposing harmful X-rays to the pati...

متن کامل

Design of a Single-Cell Positioning Controller Using Electroosmotic Flow and Image Processing

The objective of the current research was not only to provide a fast and automatic positioning platform for single cells, but also improved biomolecular manipulation techniques. In this study, an automatic platform for cell positioning using electroosmotic flow and image processing technology was designed. The platform was developed using a PCI image acquisition interface card for capturing ima...

متن کامل

A Prospective Cohort Evaluation of a Robotic, Auto-Navigating Operating Microscope

The unique challenges inherent to microneurosurgery demand that we stay on the forefront of new surgical technologies. Many believe the next major technological advance in neurosurgery will be the widespread application of image-guided robotics in the operating room. We evaluated a novel technology for image-guided robotic auto-navigation of the operating microscope in a prospectively enrolled ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009