Ijpres a Configurable Low Power Mixed Signal for Portable Ecg Monitoring System

نویسندگان

  • BAYYA RAMESH
  • P.NAGESWARA RAO
  • Bayya Ramesh
چکیده

A mixed-signal ECG System-on-Chip (SoC) that is capable of implementing configurable functionality with low-power consumption for portable ECG monitoring applications. A low-voltage and high performance analog front-end extracts 3-channel ECG signals and single channel electrode-tissueimpedance (ETI) measurement with high signal quality. This can be used to evaluate the quality of the ECG measurement and to filter motion artifacts. A custom digital signal processor consisting of 4-way SIMD processor provides the configurability and advanced functionality like motion artifact removal and R peak detection. A built-in 12-bit analog-todigital converter (ADC) is capable of adaptive sampling achieving a compression ratio of up to 7, and loop buffer integration reduces the power consumption for on-chip memory access. The SoC is implemented in 0.18 μm CMOS process and consumes 32 μW from a 1.2 V while heart beat detection application is running, and integrated in a wireless ECG monitoring system with Bluetooth protocol. Thanks to the ECG SoC, the overall system power consumption can be reduced significantly. The AFE supports concurrent 3-channel ECG monitoring, with impedance measurement and bandpower extraction. The custom digital signal processor consisting of a 4-way SIMD processor provides configurability for a wide range of application and advanced functionality like motion artifact removal, accurate R peak detection algorithm, arrhythmia classification and HRV analysis. Various algorithms are possible, allowing different power-performance trade-offs depending on the application requirements. An adaptive sampling ADC significantly reduces the equivalent data-rate of the ADC output without affecting the information content of the input signal, leading to a reduction of data memory access and processing complexity in the DSP domain. The loop buffer integration enables reduction in the access power of the program memory. The presented SoC consumes a best-in-class power consumption of only 31.1 W from a 1.2 V supply in beat detection mode. The SoC has been integrated in a wireless ECG monitoring system with Bluetooth protocol. Thanks to the advanced features of the SoC like adaptive sampling and local processing, which includes motion artifact removal and accurate R peak detection, the monitoring system can reduce the overall power consumption by factor of 20 compare to a generic system without local processing. This allows to long-term and continuous high integrity signal monitoring and also reduces the system formfactor.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and Comparative Analysis of ECG Data Acquisition System using Low Power Microcontroller

Electrocardiogram (ECG) is the most commonly used bio-medical signal for diagnostic purpose. It can be used to diagnose heart disease, identify cardiac arrhythmias, and evaluate effect of drugs. Earlier the ECG systems were designed to be used in hospitals and clinics, but now there is an increased demand for the ECG machines that can be used as a lifestyle product for routine health monitoring...

متن کامل

A 1.2v Improved Operational Amplifier for Bio- Medical Applications

In recent years, there is an ever-growing demand for low-power and low-noise mixed signal integrated circuits for applications such as portable medical systems. A high level of system integration is required to implement bio-potential system with mixed signal circuits. The most commonly observed bio-potentials used for medical diagnoses are monitored non-invasively with electrodes placed on the...

متن کامل

An Improved Micro-power Pre-amplifier for Dry-electrode ECG Recording

This paper describes the development of a very low-power pre-amplifier intended for use in pasteless-electrode recording of the human electrocardiogram. The expected input signal range is 100μV 10mV from a lead II electrode configuration. The amplifier provides a gain of 42dB in a 3dB bandwidth of 0.05Hz 2kHz with an input impedance of 280MΩ and a CMRR of greater than 80dB. Its gain and phase c...

متن کامل

طراحی و ساخت یک سیستم تشخیص خواب آلودگی راننده مبتنی بر پردازش‌گر سیگنال TMS320C5509A

Every year, many people lose their lives in road traffic accidents while driving vehicles throughout the world. Providing secure driving conditions highly reduces road traffic accidents and their associated death rates. Fatigue and drowsiness are two major causes of death in these accidents; therefore, early detection of driver drowsiness can greatly reduce such accidents. Results of NTSB inves...

متن کامل

A novel low-complexity digital filter design for wearable ECG devices

Wearable and implantable Electrocardiograph (ECG) devices are becoming prevailing tools for continuous real-time personal health monitoring. The ECG signal can be contaminated by various types of noise and artifacts (e.g., powerline interference, baseline wandering) that must be removed or suppressed for accurate ECG signal processing. Limited device size, power consumption and cost are critica...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016