Comparative Study of Bunch Length and Arrival Time Measurements at Flash

نویسندگان

  • A. Azima
  • S. Düsterer
  • M. Hüning
  • E.-A. Knabbe
  • M. Roehrs
  • V. Rybnikov
  • A. Winter
  • M. Ross
چکیده

Diagnostic devices to precisely measure the longitudinal electron beam profile and the bunch arrival time require elaborate new instrumentation techniques. At FLASH, two entirely different methods are used. The bunch profile can be determined with high precision by a transverse deflecting RF structure, but the method is disruptive and does not allow to monitor multiple bunches in a macro-pulse train. It is therefore complemented by two non-disruptive electrooptical devices, called EO and TEO. The EO setup uses a dedicated diagnostic laser synchronized to the machine RF. The longitudinal electron beam profile is encoded in the intensity profile of a chirped laser pulse and analyzed by looking at the spectral composition of the pulse. The second setup, TEO, utilizes the TiSa-based laser system used for pump-probe experiments. Here, the temporal electron shape is encoded into the spatial dimension of the laser pulse by an intersection angle between the laser and the electron beam at the EO-crystal. In this paper, we present a comparative study of bunch length and arrival time measurements performed simultaneously with all three experimental techniques.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Femtosecond Resolution Bunch Arrival Time Monitor

A need for femtosecond resolution beam arrival time measurements has arisen with the transition from manypicosecond-long bunches in ring-based accelerators to a few femtosecond-long bunches in high-gain free-electron lasers. Here we present an electro-optical detection scheme that uses the signal of a beam pick-up to modulate the intensity of a femtosecond laser pulse train. By detecting the en...

متن کامل

High Precision Sc Cavity Diagnostics with Hom Measurements

Experiments at the FLASH linac at DESY have demonstrated that the Higher Order Modes induced in Superconducting Cavities can be used to provide a variety of beam and cavity diagnostics. The centers of the cavities can be determined from the beam orbit which produces minimum power in the dipole HOM modes. The phase and amplitude of the dipole modes can be used as a high resolution beam position ...

متن کامل

Sensitivity and Tolerance Analysis of a New Bunch Arrival Time Monitor Pickup Design for Flash and Xfel

New pickup designs for a Bunch Arrival time Monitor (BAM) at the Free Electron Laser in Hamburg (FLASH) have been developed and simulated [1, 2] with CST PARTICLE STUDIO R ©. With regard to the signal characteristics and manufacturability a cone-shaped pickup was selected as a prospective candidate. At high frequencies, small manufacturing tolerances might have great influence on the pickup sig...

متن کامل

FLASH free-electron laser single-shot temporal diagnostic: terahertz-field-driven streaking

The commissioning of a terahertz-field-driven streak camera installed at the free-electron laser (FEL) FLASH at DESY in Hamburg, being able to deliver photon pulse duration as well as arrival time information with ∼10 fs resolution for each single XUV FEL pulse, is reported. Pulse durations between 300 fs and <15 fs have been measured for different FLASH FEL settings. A comparison between the X...

متن کامل

Bunch - Length and Beam - Timing Monitors in the SLC Final Focus

During the 1997/98 luminosity run of the Stanford Linear Collider (SLC), two novel RF-based detectors were brought into operation, in order to monitor the interaction-point (IP) bunch lengths and uctuations in the relative arrival time of the two colliding beams. Both bunch length and timing can strongly a ect the SLC luminosity and had not been monitored in previous years. The two new detector...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006